Related Experiment Video
Updated: Jan 23, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Clinical Applications of Technetium-99m Quantitative Single-Photon Emission Computed Tomography/Computed Tomography
Won Woo Lee1,2,
11Department of Nuclear Medicine, Seoul National University Bundang Hospital, Seoul National University College of Medicine, 82, Gumi-ro 173 Beon-gil, Bundang-gu, Seongnam-si, Gyeonggi-do, Seoul, 13620 South Korea.
Abstract:
Single-photon emission computed tomography/computed tomography (SPECT/CT) is an already established nuclear imaging modality. Co-registration of functional information (SPECT) with anatomical images (CT) paved the way to the wider application of SPECT. Recent advancements in quantitative SPECT/CT have made it possible to incorporate quantitative parameters, such as standardized uptake value (SUV) or %injected dose (%ID), in gamma camera imaging. This is indeed a paradigm shift in gamma camera imaging from qualitative to quantitative evaluation. In fact, such quantitative approaches of nuclear imaging have only been accomplished for positron emission tomography (PET) technology. Attenuation correction, scatter correction, and resolution recovery are the three main features that enabled quantitative SPECT/CT. Further technical improvements are being achieved for partial-volume correction, motion correction, and dead-time correction. The reported clinical applications for quantitative SPECT/CT are mainly related to Tc-99m-labeled radiopharmaceuticals: Tc-99m diphosphonate for bone/joint diseases, Tc-99m pertechnetate for thyroid function, and Tc-99m diethylenetriaminepentaacetic acid for measurement of glomerular filtration rate. Dosimetry before trans-arterial radio-embolization is also a promising application for Tc-99m macro-aggregated albumin. In this review, clinical applications of Tc-99m quantitative SPECT/CT will be discussed.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
04:40Identifying Coronary Artery Calcification on Non-gated Computed Tomography Scans
Published on: August 28, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Design Example: Traverse Angle Computations