LEFT VENTRICULAR EJECTION FRACTION: COMPARISON BETWEEN TRUE VOLUME-BASED MEASUREMENTS AND AREA-BASED ESTIMATES

Dawei Liu1, Isabelle Peck1,2, Shusil Dangi1

  • 1Chester F. Carlson Center for Imaging Science, Rochester Institute of Technology, Rochester, NY, USA.

Proceedings. IEEE Western New York Image and Signal Processing Workshop
|June 25, 2019
PubMed

Insights

Cardiologists often underestimate left ventricular ejection fraction (LVEF) by using 2D area changes. This study confirms volume-based measurements are more accurate for assessing cardiac function.

Area of Science:

  • Cardiology
  • Medical Imaging
  • Biomedical Engineering

Background:

  • Left ventricular ejection fraction (LVEF) is a key metric for cardiac health and treatment decisions.
  • Echocardiography (ultrasound) is the standard non-invasive method for LVEF assessment.
  • Current clinical practice often relies on 2D image analysis for LVEF estimation.

Purpose of the Study:

  • To investigate the discrepancy between area-based and volume-based LVEF calculations.
  • To validate whether 2D area estimations underestimate true LVEF.
  • To emphasize the importance of volumetric measurements for accurate cardiac assessment.

Main Methods:

  • Utilized idealized left ventricular (LV) geometry models (truncated prolate spheroid, paraboloid).
  • Calculated cross-sectional areas and volumes from simulated LV shapes.
  • Employed a 3D reconstruction algorithm using multi-plane 2D ultrasound data.

Main Results:

  • Mathematical models showed area-based LVEF (41 ±4.7%) was lower than volume-based LVEF (55 ±5.7%).
  • 3D reconstruction yielded area-based LVEF (35 ±11.9%) and volume-based LVEF (48.0 ±14.0%).
  • Area-based LVEF consistently underestimated volume-based LVEF by 13-14% across models.

Conclusions:

  • 2D area-based LVEF measurements significantly underestimate true cardiac function.
  • Volume-based LVEF calculations provide a more accurate assessment of the left ventricle.
  • Accurate LVEF assessment necessitates volumetric analysis of the LV blood pool.

Related Concept Videos

True Stress and True Strain01:28

True Stress and True Strain

Engineering stress is calculated as the load divided by the original, undeformed cross-sectional area. It approximates a material under load. This approximation is especially relevant post-yield in ductile materials. Though engineering stress-strain diagrams are often used for their convenience and accessibility, they can sometimes fall short in accuracy, particularly when dealing with large strain values.
In contrast, true stress offers a more precise portrayal. It is computed by dividing the...
810
The Sense of Self: Reflected Self-Appraisal and Social Comparison02:57

The Sense of Self: Reflected Self-Appraisal and Social Comparison

According to Charles Cooley, we base our image on what we think other people see (Cooley 1902). We imagine how we must appear to others, then react to this speculation. We don certain clothes, prepare our hair in a particular manner, wear makeup, use cologne, and the like—all with the notion that our presentation of ourselves is going to affect how others perceive us. We expect a certain reaction, and, if lucky, we get the one we desire and feel good about it. But more than that, Cooley...
55.5K
Base Excision Repair01:54

Base Excision Repair

One of the common DNA damages is the chemical alteration of single bases by alkylation, oxidation, or deamination. The altered bases cause mispairing and strand breakage during replication. This type of damage causes minimal change to the DNA double helix structure and can be repaired by the base excision repair (BER) pathways. BER corrects damaged DNA sequences by removing the damaged base and restoring the original base sequence using the complementary strand as a template.
The first step of...
26.1K
Acid-Base Titration Curves02:23

Acid-Base Titration Curves

A titration curve is a plot of some solution property versus the amount of added titrant. For acid-base titrations, solution pH is a useful property to monitor because it varies predictably with the solution composition and, therefore, may be used to monitor the titration’s progress and detect its endpoint. Acid-base titration can be performed with a strong acid and a strong base, a strong acid and a weak base, or a strong base and a weak acid.
For a titration carried out for 25.00 mL of...
140.5K
Lewis Acids and Bases02:33

Lewis Acids and Bases

In 1923, G. N. Lewis proposed a generalized definition of acid-base behavior in which acids and bases are identified by their ability to accept or to donate a pair of electrons and form a coordinate covalent bond.
A coordinate covalent bond (or dative bond) occurs when one of the atoms in the bond provides both bonding electrons. For example, a coordinate covalent bond occurs when a water molecule combines with a hydrogen ion to form a hydronium ion. A coordinate covalent bond also results when...
48.2K
Weak Base Solutions03:21

Weak Base Solutions

Some compounds produce hydroxide ions when dissolved by chemically reacting with water molecules. In all cases, these compounds react only partially and so are classified as weak bases. These types of compounds are also abundant in nature and important commodities in various technologies. For example, global production of the weak base ammonia is typically well over 100 metric tons annually, being widely used as an agricultural fertilizer, a raw material for chemical synthesis of other...
24.9K