Related Experiment Video
Updated: Jan 23, 2026

Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
Short Versus Long Cephalomedullary Nails for Pertrochanteric Hip Fractures: A Randomized Prospective Study
Steven F Shannon1, Brandon J Yuan, William W Cross
1Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN.
Objective:
To compare functional and clinical outcomes in patients with pertrochanteric hip fractures treated with either a short (SN) or long (LN) cephalomedullary nail.
Design:
Prospective, randomized.
Setting:
Clinical investigation was performed at the Mayo Clinic's Level 1 Trauma Center in Rochester, MN.
Patients/Participants:
Two hundred twenty patients with intertrochanteric fractures were prospectively randomized to an SN or LN cohort. A total of 168 patients (SN, n = 80; LN, n = 88) had a mean follow-up of 13.9 months. Fifty-two patients did not meet the minimum 3-month follow-up. Demographics were comparable between the cohorts.
Main Outcome Measures:
The primary outcome measurement was functional outcome evaluated by Short Form (SF-36) and Harris Hip scores (HHS) at 3 months. Secondary outcomes included implant failure, peri-implant fracture, mortality, operative time, estimated blood loss, and reoperation.
Results:
SN and LN cohorts were comparable in all aspects of the SF-36. There was a clinically insignificant difference in the HHS between cohorts. Patients treated in the SN cohort experienced shorter operative times but did not differ in tip-to-apex distance or subtrochanteric fracture extension. There was no difference in implant cutout, deep surgical site infection, or peri-implant fractures.
Conclusions:
Patients treated with SNs or LNs for pertrochanteric femur fractures experienced comparable functional outcomes as measured by SF-36 and HHS. When compared with the LN cohort, SN patients experienced no difference in peri-implant fracture or lag-screw cutout and tolerated up to 3 cm of subtrochanteric fracture line extension.
Level Of Evidence:
Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Related Concept Videos
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Accessory Structures of the Skin: Nails
The main components of a nail include the following.
Nail Plate: The nail plate is the visible portion of the nail that extends beyond the fingertips or toes. It is a hard, translucent...
Random Error
Random Variables
Uppercase letters such as X or Y denote a random variable. Lowercase letters like x or y denote the value of a random variable. If X is a random variable, then X is written in words, and x is given as a number.
For example, let X = the...
Randomized Experiments
Simple randomization
Simple...
Random and Systematic Errors