Related Experiment Video
Updated: Jan 23, 2026

Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as
Eric T Geier1, Rebecca J Theilmann2, Chantal Darquenne1
1Pulmonary Imaging Laboratory, Department of Medicine, University of California, San Diego.
Abstract:
Specific ventilation imaging (SVI) is a functional magnetic resonance imaging technique capable of quantifying specific ventilation - the ratio of the fresh gas entering a lung region divided by the region's end-expiratory volume - in the human lung, using only inhaled oxygen as a contrast agent. Regional quantification of specific ventilation has the potential to help identify areas of pathologic lung function. Oxygen in solution in tissue shortens the tissue's longitudinal relaxation time (T1), and thus a change in tissue oxygenation can be detected as a change in T1-weighted signal with an inversion recovery acquired image. Following an abrupt change between two concentrations of inspired oxygen, the rate at which lung tissue within a voxel equilibrates to a new steady-state reflects the rate at which resident gas is being replaced by inhaled gas. This rate is determined by specific ventilation. To elicit this sudden change in oxygenation, subjects alternately breathe 20-breath blocks of air (21% oxygen) and 100% oxygen while in the MRI scanner. A stepwise change in inspired oxygen fraction is achieved through use of a custom three-dimensional (3D)-printed flow bypass system with a manual switch during a short end-expiratory breath hold. To detect the corresponding change in T1, a global inversion pulse followed by a single shot fast spin echo sequence was used to acquire two-dimensional T1-weighted images in a 1.5 T MRI scanner, using an eight-element torso coil. Both single slice and multi-slice imaging are possible, with slightly different imaging parameters. Quantification of specific ventilation is achieved by correlating the time-course of signal intensity for each lung voxel with a library of simulated responses to the air/oxygen stimulus. SVI estimations of specific ventilation heterogeneity have been validated against multiple breath washout and proved to accurately determine the heterogeneity of the specific ventilation distribution.
More Related Videos
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging
Resonance
Atomic Nuclei: Magnetic Resonance
Nuclear Magnetic Resonance (NMR): Overview
NMR spectroscopy generates a spectrum where the characteristic absorption frequencies of the sample are...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...

