Application of trans-thoracic echocardiography and coronary CT angiography to diagnose mitral valve prolapse
Jingbo Li1, Yun Zhang2, Liulong Zhang2
1Department of Ultrasound, Dongying People's Hospital of Shandong, Dongying, 257091, China.
Insights
Coronary CT angiography offers superior accuracy in detecting mitral valve prolapse compared to trans-thoracic echocardiography. This advanced imaging technique provides more reliable measurements of mitral valve motion and thickness.
Area of Science:
- Cardiology
- Medical Imaging
- Diagnostic Techniques
Background:
- Multi-detector cardiac CT is established for assessing heart valve morphology and function.
- Mitral valve prolapse (MVP) requires accurate diagnostic methods for evaluation.
Purpose of the Study:
- To compare the diagnostic performance of coronary CT angiography (CCTA) against trans-thoracic echocardiography (TTE) in patients with MVP.
- To evaluate the accuracy of CCTA in assessing mitral valve leaflet motion and thickness.
Main Methods:
- CCTA and TTE were utilized to measure the movement range and thickness of the mitral valve leaflets.
- Ultrasonic parameters from CCTA were considered the reference standard for comparison.
Main Results:
- CCTA demonstrated high accuracy (95.6%) and sensitivity (69.2%) for detecting mitral valve motion amplitude, with a significant P-value (<0.001).
- CCTA measurements for mitral leaflet thickness and motion range were (2.00 ± 0.54) mm and (3.76 ± 2.1) mm, respectively.
- TTE measurements for mitral leaflet thickness and motion range were (1.95 ± 0.22) mm and (1.5 ± 2.28) mm, respectively.
Conclusions:
- CCTA exhibits higher accuracy and reliability in diagnosing mitral valve prolapse compared to TTE.
- The findings suggest CCTA is a valuable tool for detailed assessment of MVP.
Objective:
At present, multi-detector cardiac CT has been widely applied in the detection of heart valve morphology and function. This study aims to compare the coronary CT angiography and trans-thoracic echocardiography for patients with mitral valve prolapse.
Methods:
CT angiography and trans-thoracic echocardiography were adopted to detect the movement range and thickness of valvula bicuspidalis. The ultrasonic parameters of CT angiography were considered as standard reference value.
Results:
Receiver operating characteristic (ROC) curve showed that the area of mitral valve motion amplitude under ROC curve was 95% detected by CT angiography with statistical significance (P < 0.001). Based on the intercept point on the ROC curve, the sensitivity and accuracy of mitral valve amplitude detected by CT angiography was 69.2 and 95.6%, the false positive and false negative rate was 5.2 and 32.4%, the predicted value of positive and negative was 92.9 and 76.9% and the consistency rate of motion range and leaf thickness detected by CT angiography was 83.3 and 47.5%. Trans-thoracic echocardiography showed that the thickness and motion range of mitral leaflet was (1.95 ± 0.22) mm and (1.5 ± 2.28) mm. The thickness and motion range of mitral leaflet that detected by CT was (2.00 ± 0.54) mm and (3.76 ± 2.1) mm.
Conclusion:
The accuracy and reliability of CT angiography for patients with mitral valve prolapse are higher than those of trans-thoracic echocardiography.
More Related Videos
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Thoracic Aorta
Diagnosing Acidosis and Alkalosis
First, the pH level is assessed to determine whether the blood pH is normal (7.35–7.45), low (acidosis), or high (alkalosis).
Next, the PCO2 and...
Mitral Stenosis I: Introduction