Achieving contrast-free ultra-low radiation exposure without compromising safety and acute efficacy through evolving
James Reiss1, Heather O'Connell2, Michael K Getman2
1PeaceHealth Southwest Medical Center Heart & Vascular, Washington, USA.
Introduction:
In general, early experience with the first-generation cryoballoon introduced an increase in radiation exposure as compared to traditional radiofrequency ablations for atrial fibrillation (AF). However, through operator vigilance and the incorporation of various techniques and technologies, procedural radiation exposure can be managed to an exceptionally low level while maintaining the safety and efficacy of the cryoballoon procedure.
Methods And Results:
A retrospective chart review of all consecutive AF ablation procedures performed by a single operator at a single high-volume center with the second-generation cryoballoon (Arctic Front Advance) was performed between 2014 and 2017. Procedural and radiation exposure data were collected and analyzed year-over-year. 307 cases were reviewed with the majority as index procedures (95%) and patients presenting in paroxysmal AF (87%). The observed median absorbed dose was 2.4 mGy (interquartile range (IQR) = 1.0,6.2) and decreased significantly from 6.7 mGy (IQR = 1.6,6.2) in 2014 to 2.0 mGy (IQR = 1.5,4.5) in 2017 (P < 0.001). Median fluoroscopy time was 0.4 min (IQR = 0.25,0.75) and demonstrated reductions from 0.75 min (IQR = 0.40,1.4) in 2014 to 0.20 min (IQR = 0.10,0.40) in 2017 (P < 0.001). No radiopaque contrast agent was used in any procedure. A complication rate of 2% (6 total events) was observed, and no cases resulted in stroke, death, permanent phrenic nerve injury, or pulmonary vein stenosis. In total, 304 of 307 (99%) procedures resulted in complete isolation of all pulmonary veins.
Conclusion:
Ultra-low radiation doses and contrast-free procedures can be achieved as part of an overall "safety-first" approach during cryoballoon AF ablation without compromising safety or acute efficacy.
Related Concept Videos
Biological Effects of Radiation
Survey Safety
Self-Efficacy
Radiation: Applications
The average...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Absorption of Radiation