Matthew E Prekker1, Crystal Donelan2, Sum Ambur2
1Department of Emergency Medicine, Hennepin County Medical Center, Minneapolis, MN, United States of America; Department of Medicine, Division of Pulmonary and Critical Care, Hennepin County Medical Center, Minneapolis, MN, United States of America.
Background:
Ventilator tidal volumes of >8 mL/kg of predicted body weight (PBW) may increase the risk of lung injury. We sought to evaluate the impact of a quality improvement intervention among intubated Emergency Department (ED) patients to protocolize the prescription of low tidal volume ventilation.
Methods:
In this before-and-after study, the average tidal volume delivered to ED patients receiving volume assist-control ventilation was compared before (2007-2014) and after (2015-2016) implementation of a ventilator initiation protocol (the quality improvement intervention). The intervention emphasized 1) measurement of the patient's height to calculate PBW and therefore tailor the tidal volume to estimated lung size (<8 mL/kg PBW), and 2) focused education and reference materials for ED physicians and respiratory therapists.
Results:
Among ventilated ED patients meeting inclusion criteria in the before (N = 2185) and after (N = 774) cohorts, the mean (±SD) tidal volume decreased from 9.0 ± 1.4 mL/kg to 7.2 ± 0.9 mL/kg PBW following the intervention (absolute difference 1.8 mL/kg, 95% confidence interval 1.7 to 1.9 mL/kg, p < 0.001). The proportion of patients receiving low tidal volume ventilation increased after the intervention (72%), as compared to before (23%). Low tidal volume ventilation continued to be utilized at 24 h after ICU admission in patients who remained intubated in the cohort following the intervention (mean tidal volume 7.3 mL/kg PBW).
Conclusions:
Pairing a ventilator initiation protocol with focused education and resources for emergency physicians and respiratory therapists was associated with a significant reduction in tidal volume delivered to ED patients.
Related Concept Videos
Tidal Forces
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Emerging Adulthood
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Nursing Interventions I: Taxonomy of Nursing Interventions
A nursing intervention is a treatment or action based on scientific concepts and knowledge from the nursing, behavioral, and physical sciences. Identifying and prioritizing nursing interventions based on the desired outcome...
Nursing Interventions II: Selecting and Classifying the Nursing Interventions