Related Experiment Video
Updated: Jan 23, 2026

Mouse Embryonic Development in a Serum-free Whole Embryo Culture System
Published on: March 1, 2014
Development of the Serum α-Fetoprotein Reference Range in Patients with Beckwith-Wiedemann Spectrum
Kelly A Duffy1, Jennifer L Cohen1, Okan U Elci2
1Division of Human Genetics, Children's Hospital of Philadelphia, Philadelphia, PA.
Objective:
To establish reference ranges for serum α-fetoprotein (AFP) at various ages in patients with Beckwith-Wiedemann spectrum (BWSp), to better predict the risk for hepatoblastoma in this population.
Study Design:
A retrospective analysis of AFP measurements collected from patients with BWSp was performed. Factors including sex, prematurity, molecular diagnosis of patients, and performing laboratory were evaluated for significant differences. In total, 1372 AFP values were collected from 147 patients and the predictive AFP values at various ages were calculated to establish reference ranges. Mixed-effects polynomial regression models were used to study various potential factors affecting log(AFP) values.
Results:
Overall, predicted AFP values declined to normal range for age (<10 ng/mL) by 14 months old. Patient sex and performing laboratory were found not to influence values. A significant difference was demonstrated between premature and nonpremature patients, and separate reference values were established. Significant differences in the predicted AFP value were not broadly apparent between molecular subtypes; however, interpretation was limited due to the small sample size of some of these subtypes.
Conclusions:
Predictive AFP values were created for premature and nonpremature patients with BWSp to aid with interpretation and monitoring of the risk for hepatoblastoma. Further analysis is needed to determine whether AFP values differ within the less common molecular subtypes of patients with BWSsp.
Related Concept Videos
The Electromagnetic Spectrum
The Electromagnetic Spectrum
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Mass Spectrum
Variation: Normal Distribution, Range, and Standard Deviation

