Methodical inaccuracy of the Z-scan method for few-cycle terahertz pulses
Maksim Melnik1, Irina Vorontsova2, Sergey Putilin2
1ITMO University, International Laboratory of Femtosecond Optics and Femtotechnologies, St. Petersburg, 197101, Russia. mmelnik@corp.ifmo.ru.
Abstract:
Modern sources of THz radiation generate high-intensity pulses allowing to observe nonlinear effects in this spectral range. To describe many nonlinear effects theoretically, it is necessary to know the nonlinear refractive index coefficient of optical materials. The work studies the applicability of the Z-scan method to determine the nonlinear refractive index coefficient in the THz frequency range for few-cycle pulses. We have discussed the correctness of the known Z-scan method for calculating the nonlinear refractive index coefficient for broadband THz radiation regarding number of cycles pulses have. We have demonstrated that the error in determining the nonlinear refractive index coefficient is always greater than 70% for true single-cycle pulses. With the increase in the number of oscillations to the measurement error shows strong dependence on the sample thickness and can vary from 2% to 90% regarding the parameters chosen. The fact that such radiation dispersion length is commensurate with the nonlinear length or even less than the latter results in the discrepancy mentioned. It is demonstrated that the decrease in the sample thickness leads to the reduction of the nonlinear refractive index coefficient determination error, and this error is <2% when the ratio between the sample thickness and the pulse longitudinal spatial size is ≤1. This can relate to the fact that the nonlinear effects in such a thin sample occur faster than the dispersion ones.
Related Concept Videos
The Scientific Method
Generally, predictions are tested using carefully-designed experiments. Based on the outcome of these...
The Scientific Method
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...