A rare cause of stroke after transcatheter aortic valve replacement: Retained foreign body
Aravinda Nanjudappa1, Abhishek Bhagat2, Mark C Bates3,4,5
1Cardiology and Structural Heart, Charleston Area Medical Center, Charleston, West Virginia.
Abstract:
The field of transcatheter aortic valve replacement (TAVR) has matured significantly with the outcome and durability data now supporting use in lower-risk patients. We present a preventable complication from early in our experience (5 years ago) that illustrates the importance of heart team communication and cautious multidiscipline cross-pollination during the formative years of a program. An 87-year old female developed confusion, slurred speech and left upper extremity weakness 1 day following TAVR with inconclusive findings on carotid artery duplex and transthoracic echocardiography. Subsequent CT-scan disclosed a linear, ring-like, structure in the ascending aorta. The foreign body (FB) was radiolucent and successfully snared via tactile sensation and anatomic landmarks informed by the CT. The extricated FB was the valvuloplasty balloon guard (BG) that was inadvertently introduced into the patient via ascending aortic large sheath access. The failure mode was traced back to the first time use of a new balloon system and unrecognized BG by the surgical physician and technician components of the Heart Team who took the lead role in device insertion due to the open chest access. Subsequently, the heart team made changes to mitigate similar future complications by sharing multidiscipline responsibility for all procedural steps and ensuring the use of all new adjuvant devices are preceded by a procedural pause and team consensus regarding device preparation and use. Additionally, the manufacturer addition of a radiopaque marker or flair on the valvuloplasty BG may be warranted.
More Related Videos
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Continuous Renal Replacement Therapy
Mitral Valve Prolapse I: Introduction
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C...
Body Temperature
Centroid of a Body
For a homogeneous body with constant density, the centroid can usually be found using equations representing a balance of the moments of the body's volume. If the...