Related Experiment Video
Updated: Jan 23, 2026

Rapid, Enzymatic Methods for Amplification of Minimal, Linear Templates for Protein Prototyping using Cell-Free Systems
Published on: June 14, 2021
A label-free and ultrasensitive DNA impedimetric sensor with enzymatic and electrical dual-amplification
Shuo-Hui Cao1, Lun-Hui Li, Wen-Yin Wei
1State Key Laboratory of Physical Chemistry of Solid Surfaces, Department of Electronic Science, Xiamen University, Xiamen 361005, P. R. China. chenz@xmu.edu.cn.
Abstract:
In this work, we report a facile, sensitive, selective, and reproducible DNA impedimetric sensor device. We demonstrate that, combined with exonuclease III, the easily prepared electrochemically reduced graphene oxide (rGO) could be a desirable platform to amplify signals in electrochemical impedance spectroscopy for ultrasensitive DNA detection. Guided by enzyme assisted target recycling, efficient interfacial tuning can be obtained, from the situation with high impedance caused by single-stranded DNA probes directly adsorbed onto rGO to the one with low impedance due to the continuous desorption of target-probe DNA hybrids and the consequent digestion of DNA probes. Just a few DNA targets can specifically trigger the enzymatic digestion of a large number of DNA probes. It is the excellent electrical conductivity of rGO that further enlarges the changes of electron transfer resistance after the removal of DNA probes. As a result of synergistically combining both enzymatic and electrical amplification, the enlarged changes of impedimetric signals can be measured to sensitively report DNA targets. The specificity has been guaranteed by the intrinsic recognition of hybrids through both rGO and exonuclease III. A limit of detection as low as 10 aM target DNA in the matrix of cell culture medium, as well as a wide linear range and good discrimination of mismatched sequences even at the one-base level, suggests its great application prospect in biosensing and biomedical analysis. It also has other advantages including easy operation, low cost, and convenient regeneration, with more competitive performance in developing impedimetric biosensors.
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
RACE - Rapid Amplification of cDNA Ends
Determining Electric Field From Electric Potential
In general, regardless of whether the electric field is uniform, it points in the direction of decreasing potential because the force on a positive...
Finding Electric Potential From Electric Field
Amplifying Signals via Enzymatic Cascade
Electric Potential Energy in a Uniform Electric Field