Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students
Published on: June 16, 2018
Feasibility of a New Wearable Device to Estimate Acute Stress in Novices During High-fidelity Surgical Simulation
Konstantinos E Georgiou1, Rossen K Dimov2,3, Nikola B Boyanov2,4
1First Department of Propaedeutic Surgery, Hippokration General Hospital of Athens, Athens Medical School, National and Kapodistrian University of Athens, Athens, Greece.
Background:
Stress associated with learning of a psychomotor task can influence the trainees learning ability. Surgical simulation is a validated training milieu designed to replicate real-life situations, prevent biases and provide objective metrics. However, the complexity of stress mechanisms and the absence of a reliable detection method make stress estimation difficult to quantify and to interpret.
Aim:
a) To assess the feasibility of a new watch-sized device to noninvasively measure stress parameters in novices during a simulation task and b) to compare its derived cardiac stress parameters to those of an ambulatory Holter monitor.
Materials And Methods:
Twenty-one novices were trained on a basic skills module. During base line, exercise, and recovery phases, all subjects wore a wearable device and data regarding blood volume pressure, heart rate, inter beat interval, electrodermal activity, and skin temperature were recorded. Additionally, Holter Monitoring was used to concomitantly capture heart rate, R-R intervals and heart rate variability. Before and after each experiment, all subjects completed the short, six-item STAI scale.
Results:
Data analysis showed: a) when compared to STAI, electrodermal activity exhibited the best correlation, sensitivity and specificity and b) the device derived cardiac parameters highly correlated with the reciprocal Holter values during all experiment phases.
Conclusion:
This wearable device is an easy to use and well accepted by the participants noninvasive tool, which can provide accurate stress estimation in our simulation setting. Additionally, it can replicate Holter derived stress related heart parameters, thus eliminating the need to wear a rather cumbersome device.
More Related Videos
10:45A Community-based Stress Management Program: Using Wearable Devices to Assess Whole Body Physiological Responses in Non-laboratory Settings
Published on: January 22, 2018
15:00Setup of Consumer Wearable Devices for Exposure and Health Monitoring in Population Studies
Published on: February 3, 2023
Related Concept Videos
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...
Estimation of k and VD of Aminoglycosides
Responses to Salt Stress
Responses to Heat and Cold Stress
Estimation of the Physical Quantities
General State of Stress
Specifically, consider a tetrahedral element where one face, labeled XYZ, is perpendicular to the line OA, and the remaining faces align with the coordinate axes with point O as the origin. At any point, such as point O, the stress tensor can be used to determine the stress...