Appropriate Methodology for EBRT and HDR Intracavitary/Interstitial Brachytherapy Dose Composite and Clinical Plan
Zhengzheng Xu1, Bryan J Traughber2, Elisha Fredman2
1Department of Radiation Oncology, University Hospitals Cleveland Medical Center, Cleveland, Ohio.
Purpose:
This study assessed the appropriateness of full parameter addition (FPA) methods with respect to the 3-dimensional deformable dose composite method for evaluating combined external beam radiation therapy (EBRT) and intracavitary brachytherapy (ICBT).
Methods And Materials:
A total of 22 patients who received EBRT and high-dose-rate ICBT were retrospectively evaluated. Split-ring and tandem applicators were used for all patients. Additional interstitial needles were used for 5 patients to supplement the implant. Deformable image registrations were performed to deform the secondary EBRT and ICBT planning computed tomography (CT) images onto the reference CT from the third fraction of ICBT. The Dice similarity coefficient was used to evaluate the quality of deformable registration. Doses were transferred to the reference CT, scaled to the equivalent dose in 2-Gy fractions and combined to create the dose composite. Eight dose-accumulation methods were evaluated and compared. D2cc and D0.1cc for organs at risk were investigated.
Results:
The differences in D2cc for rectum, bladder, sigmoid, and bowel between the FPA method for whole-pelvis EBRT and ICBT, calculated using an old American Brachytherapy Society worksheet (FPA_Eh + I_old) and deformable composite for EBRT with boosts and ICBT (Def_E + B + I) were -2.19 ± 1.37 Gyα/β = 3, -0.64 ± 1.13 Gyα/β = 3, -2.06 ± 2.71 Gyα/β = 3, and -1.59 ± 0.89 Gyα/β = 3, respectively. The differences in D2cc for rectum, bladder, sigmoid, and bowel between the new ABS worksheet (FPA_Eh + B + I_abs) and the Def_E + B + I method were 1.21 ± 1.22 Gy α/β = 3, 1.93 ± 1.38 Gyα/β = 3, 0.72 ± 1.12 Gyα/β = 3, and 1.19 ± 1.46 Gyα/β = 3, respectively. Differences in dose-volume histogram parameter values among Def_E + B + I and other FPA methods were not statistically significant (P > .05).
Conclusions:
Compared with the FPA-based method, deformable registration-based dose composites demonstrated lower OAR D2cc and D0.1cc values; however, the differences were not statistically significant. The current ABS-recommended FPA-based sheet can serve as an acceptable plan evaluation tool for clinical purposes.
Related Concept Videos
Drug Dosing: Geriatric Patients
Drug Dosing: Obese Patients
Nursing Process for Patient and Caregiver Teaching II: Planning and Implementation
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Classifying Matter by Composition
According to its composition, the matter can be classified into two broad categories — pure substances and mixtures.
A pure substance is a form of matter that has a constant composition throughout with uniform properties. For example, any sample of sucrose has the same composition and same physical properties, such as melting point, color, and sweetness, regardless of the source from which it is isolated.
A mixture is composed of two or...
Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation
Irritable Bowel Syndrome (IBS) is classified into subtypes based on the predominant bowel habits as determined by the Bristol Stool Form Scale (BSFS). The subtypes are: