In vitro hemodynamic assessment of a novel polymeric transcatheter aortic valve
Megan Heitkemper1, Hoda Hatoum2, Lakshmi Prasad Dasi1
1Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA.
Abstract:
Transcatheter aortic valve replacement (TAVR) is a life-saving alternative to surgical intervention. However, the identification of features associated with poor outcomes, including residual paravalvular leakage (PVL), leaflet calcification, and subclinical leaflet thrombosis, are cause to be concerned about valve durablilty (Mylotte and Piazza, 2015a, 2015b; Dasi et al., 2017; Makkar et al., 2015; Kheradvar et al., 2015a). The aim of this study is to optimize the potential of a hyaluronan (HA) enhanced polymeric transcatheter aortic valve (HA-TAV) that has promised to reduce blood damage causing-turbulent flow while maintaining durability. HA-enhanced linear low-density polyethylene (LLDPE) leaflets were sutured to novel cobalt chromium stents, size 26 mm balloon expandable stents. Hemodynamic performance was assessed in a left heart simulator under physiological pressure and flow conditions and compared to a 26 mm Medtronic Evolut and 26 mm Edwards SAPIEN 3. High-speed imaging and particle image velocimetry (PIV) were performed. The HA-TAV demonstrated an effective orifice area (EOA) within one standard deviation of the leading valve, SAPIEN 3.The regurgitant fraction (RF) of the HA-TAV (11.23 ± 0.55%) is decreased in comparison the Evolut (15.74 ± 0.73%) and slightly higher than the SAPIEN 3 (10.92 ± 0.11%), which is considered trace regurgitation according to valve standards. A decreased number of higher principal Reynolds shear stresses were shown for the HA-TAV at each cardiac phase. The HA-TAV is directly comparable and in some cases superior to the leading commercially available prosthetic heart valves in in-vitro hemodynamic testing.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Olefin Metathesis Polymerization: Ring-Opening Metathesis Polymerization (ROMP)
Actin Polymerization
The nucleation phase involves forming a stable nucleus consisting of three actin monomers to form a new actin filament. Actin-binding proteins such as formins and Arp2/3 complex help filament growth post-nucleation. The Formins form straight...
Mitral Valve Prolapse I: Introduction
Step-Growth Polymerization: Overview
Many natural and synthetic polymers are produced by...