Related Experiment Video
Updated: Jan 23, 2026

Urethral Stricture Induction Followed by Buccal Mucosa Graft Urethroplasty in a Rat Model
Published on: April 28, 2023
Is it possible to estimate urethral mobility based on maximal urethral closure pressure measurements?
Objective:
Is it possible to estimate urethral mobility based on MUCP measurements?
Design:
Retrospective study.
Setting:
Department of Gynecology and Obstetrics, 1st Medical Faculty, Charles University, General Teaching Hospital, Prague.
Methods:
This retrospective study included 567 patients from three prospective studies within years 2002 to 2009. Ultrasound examination was performed in 560 of them and maximal urethral closure pressure (MUCP) values were measured in 507 women. The MUCP was defined as the difference between maximum urethral pressure and bladder pressure. An ultrasound examination was performed using the transperineal approach in accordance with the recommendations of the German Urogynecology Working Group and ICS, IUGA terminology. The mobility was expressed as a distance between the position at rest and at the maximal Valsalva manoeuvre. Data were summarized as mean and median, with SD and quantile range for measures of variability. Either a matched pairs t-test or Wilcoxon test was used for statistical evaluation.
Results:
Mean MUCP was 47.4 cm H2O (SD 22.2, first quantile 32, third quantile 62). Mean urethral descent was 20.6 mm (SD 8.2, first quantile 14.9, third quantile 25.6 mm). Using regression analysis there was an increase in urethral descent; this difference is statistically significant. For a MUCP increase of 10 cm H2O we could estimate an increase in urethral descent of 1.1 mm.
Conclusion:
We established a statistically significant relationship between urethral descent and MUCP. Unfortunately those differences are not clinically relevant, especially for MUCP over 20 cm H2O. For MUCP below 20 cm H2O low urethral descent is more likely. Clinical use of MUCP as predictor of urethral descent is limited due to the high variability involved.
More Related Videos
Related Concept Videos
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
Measurement of Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
What are Estimates?
The estimate for the mean of a sample is denoted by ͞x, whereas the mean of the population is designated as μ. Further, parameters such...