Related Experiment Video
Updated: Jan 23, 2026

Parallel-plate Flow Chamber and Continuous Flow Circuit to Evaluate Endothelial Progenitor Cells under Laminar Flow Shear Stress
Published on: January 17, 2012
Evaluation of the Intracranial Flow Alteration during Manual Syringe and Continuous Pump Aspiration
Hideo Okada1, Yoshikazu Matsuda1, Alex Malisch2
1Department of Neurological Surgery, Rush University Medical Center, Chicago, Illinois; Department of Neurosurgery, Wakayama Rosai Hospital, Wakayama City, Japan.
Goals:
While mechanical thrombectomy (MT) has been shown to be effective in the treatment of acute large vessel occlusions, adjunctive measures, such as balloon guide catheters (BGC) and aspiration techniques, are utilized heterogeneously. Clarifying the effects of aspiration applied to the anterior cerebral circulation with proximal flow arrest can shed light on embolic protection during MT.
Materials And Methods:
Manual and pump aspiration were applied through a BGC in a synthetic cerebrovascular model with a 60 ml syringe and a Penumbra pump, respectively. Flow direction was observed during the procedure with fluorescent particles and ultraviolet light. Flow rates were monitored at the simulated internal carotid artery and middle cerebral artery (MCA).
Findings:
Both aspiration methods produced retrograde flow in all the modeled cerebrovascular segments. In the syringe aspiration methods, an interval phase occurred during the experimental trial in which suction forces paused and MCA flow became anterograde through posterior communication artery collateral circulation.
Conclusion:
Flow patterns vary with different methods of aspiration. With proximal flow arrest, continuous aspiration methods induce constant retrograde flow in all vessels, whereas manual aspiration demonstrates various flow changes, including periods of anterograde flow during the procedure, which may be less effective at distal re-embolization prevention.
More Related Videos
09:08Three-dimensional Printing of Thermoplastic Materials to Create Automated Syringe Pumps with Feedback Control for Microfluidic Applications
Published on: August 30, 2018
10:34The Fabrication and Operation of a Continuous Flow, Micro-Electroporation System with Permeabilization Detection
Published on: January 7, 2022
Related Concept Videos
ATP Driven Pumps III: V-type Pumps
The peripheral or cytosolic V1 domain with eight subunits is involved in ATP hydrolysis. The integral or transmembrane V0 domain containing at least five subunits...
ATP Driven Pumps II: P-type Pumps
A typical P-type pump has three cytosolic domains: nucleotide-binding (N), phosphorylation (P), and activator (A) domains. These domains are connected to the membrane-spanning helices by short amino acid segments. ATP hydrolysis and covalent phosphoenzyme intermediate formation are crucial parts of the catalytic cycle. At the highly...
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes...
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Altered States of Awareness
The ingestion of substances like stimulants or hallucinogens leads to chemical alterations in the brain...
Refrigerators and Heat Pumps
A household refrigerator removes heat from...