Related Experiment Video
Updated: Jan 23, 2026

Dynamic Navigation for Dental Implant Placement
Published on: September 13, 2022
Pilot-drill guided vs. full-guided implant insertion in artificial mandibles-a prospective laboratory study in
Matthias C Schulz1, Francisca Hofmann2, Ursula Range3
1Department of Oral and Maxillofacial Surgery, Faculty of Medicine "Carl Gustav Carus", Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany. matthias.schulz@uniklinikum-dresden.de.
Background:
As a growing field in dentistry, the practical education during the undergraduate curriculum in implant dentistry should be extended. Not only the theoretical background but also practical skills are crucial to place implants in patients. In order to determine the exact implant position, several positioning aids are available. In the present laboratory study, the accuracy of implant insertion using two different guiding modes in a group of inexperienced participants was assessed.
Methods:
After three-dimensional planning using the data of a cone beam computed tomography of artificial mandibles, surgical templates were manufactured by thermoforming. In region 35, a sleeve for the pilot drill was used, whereas in region 45, a sleeve allowing a full-guided implant insertion was inserted. Subsequently, a total of 104 implants were placed by 52 undergraduates. Radiographical assessment of the three-dimensional accuracy was performed. Furthermore, the time required to insert the implants was recorded. Statistical analysis followed.
Discussion:
When comparing the three-dimensional accuracy of the virtually planned to the actual inserted implant, a statistically significantly higher accuracy in three-dimensional angulation was achieved for the full-guided (3.388 ± 1.647°) compared to the pilot-drill guided mode (5.792 ± 3.290°). Furthermore, the time required to insert the implant was shorter for the full-guided template (6.23 ± 1.78 min) vs. for the pilot-drill guided (8.84 ± 2.39 min). Both differences reached a statistical significance (p < 0.001).
Conclusion:
Within the limit of this laboratory study, the results suggest that inexperienced surgeons benefit from a full-guided implant insertion. However, the clinical effects have to be discussed as the mismatch was varying in the decimillimeter range.
More Related Videos
10:52Microelectrode Guided Implantation of Electrodes into the Subthalamic Nucleus of Rats for Long-term Deep Brain Stimulation
Published on: October 2, 2015
14:59Neuronavigation and Laparoscopy Guided Ventriculoperitoneal Shunt Insertion for the Treatment of Hydrocephalus
Published on: October 14, 2022
Related Concept Videos
Pilot and Numeric Relaying
Student t Distribution
The Student t distribution was developed by William S. Goset (1876–1937) of the...
Serum Laboratory Studies, Stool Test, Breath Test
Microsoft Excel: Student's t-Test
To conduct a t-test in Excel, use the T.TEST function or the "Data...
Comparing Experimental Results: Student's t-Test
Natural and Artificial Concepts