A shortened uncemented stem offers comparable positioning and increased metaphyseal fill compared to a standard
Alexandre Jacquel1, Augustin Le Viguelloux2, Jeremy Valluy3
1Ramsay Générale de Santé, Clinique de la Sauvegarde, Lyon-Ortho-Clinic, 8 Avenue Ben Gourion, 69009, Lyon, France.
Background:
Shortened stems are increasingly used in uncemented total hip arthroplasty (THA) as they represent a compromise between the metaphyseal anchorage of short stems and the facilitated axial alignment of standard stems. The purpose of this study was to compare the metaphyseal canal-fill ratio (CFR) and axial alignment of a shortened double-tapered stem with those of a standard stem. The hypothesis was that the shortened stem would achieve greater metaphyseal fill and comparable axial alignment.
Methods:
The authors reviewed routine follow-up anteroposterior radiographs taken 2 months after THA to evaluate metaphyseal fill and axial alignment of a shortened stem (n = 96) and a standard stem (n = 101). The CFR was calculated at the level of the tip and superior margin of the lesser trochanter. Stem alignment was defined as the angle between the stem axis and the proximal anatomic femoral axis. Stems were classified as being in varus or valgus alignment if they deviated by more than 3° from the anatomic axis of the femur.
Results:
Hips implanted with shortened and standard stems had comparable demographics and axial alignment (1.1° ± 1.7° vs 0.8° ± 1.2°; p = 0.331). However, varus alignment was observed in 5% of shortened stems compared to only 1% of standard stems, though this difference was not significant (p = 0.111). The femoral CFR was greater using shortened stems than using standard stems, both at the level of the tip of the lesser trochanter (0.91 ± 0.05 vs 0.85 ± 0.08; p < 0.001) and at its superior margin (0.76 ± 0.06 vs 0.72 ± 0.07; p < 0.001).
Conclusions:
Compared to the standard stem, the shortened stem had increased metaphyseal filling and equivalent alignment. These findings suggest that shortened stems could provide adequate metaphyseal fixation and correct alignment. Further studies remain necessary to evaluate how shortened stems perform in terms of osseointegration, clinical outcomes and survival.
Related Concept Videos
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Comparing the Survival Analysis of Two or More Groups
Comparing Experimental Results: Student's t-Test
Comparative Excretory Systems
Comparing Mitochondrial, Chloroplast, and Prokaryotic Genomes
Comparing Intermolecular Forces: Melting Point, Boiling Point, and Miscibility
Temporary attractive forces like dispersion are present in all molecules, whether they are polar or nonpolar. They...