Related Experiment Video
Updated: Jan 23, 2026

Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
Initial experience with a novel re-sterilisable decapolar electrophysiology catheter
Anna L Wilson1,2, Kellie A Timmins3,4, Rosemary F Allen3,4
1Cardiology Department, Waikato Hospital, Hamilton, New Zealand. anna.wilson@waikatodhb.health.nz.
Purpose:
Diagnostic electrophysiology catheters are single-use and their expense can act as a barrier to their use. A decapolar catheter with a re-sterilisable handle and inner core was developed, along with a disposable outer sheath. This initial experience evaluated the performance of the Khelix partially recyclable steerable decapolar electrophysiology catheter.
Methods:
Sequential patients requiring a decapolar steerable catheter were included in the study. Parameters such as time to positioning from right femoral vein, fluoroscopy time and dose, pacing and sensing thresholds, and the requirement for reposition and/or support sheath were recorded. A retrospective analysis from cases using a standard disposable decapolar catheter was used to compare CS cannulation success, support sheath requirement and cost.
Results:
11 re-sterilisable catheter handles were used in 64 patients, each time with a disposable sheath, at two New Zealand centres from December 2017 to June 2018. Pre-defined safety measures were met in all patients, with no catheter-related adverse events. The catheter was successfully positioned in the coronary sinus for 59 cases (92%). Based on initial manufacturer recommendations, the inner recyclable portion of the catheter was able to be re-used successfully up to 12 times with re-sterilisation between cases.
Conclusions:
This initial study of an innovative, partially reusable, steerable decapolar electrophysiology catheter demonstrates that it may be used safely and successfully. Use of such a catheter may decrease the cost required for electrophysiology studies.
Related Concept Videos
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...
Initiation of Translation
Transcription Initiation
The promoters and enhancers and their accessory proteins allow tight regulation of...
S-Cdk Initiates DNA Replication
Two states at the origin of replication
In eukaryotes, the initiation of replication occurs at many sites on the chromosomes, called the origins of...
What is an Experiment?
Thomson's e/m Experiment
A particle with charge q, speed v, and mass m enters an area from the top, where the magnetic and electric fields are perpendicular both to the particle's motion and to one another. The magnetic...