Applicability of quantitative flow ratio for rapid evaluation of intermediate coronary stenosis: comparison with instantaneous wave-free ratio in clinical practice
Related Experiment Video
Updated: Jan 22, 2026

Evaluation of Coronary Flow Reserve After Myocardial Ischemia Reperfusion in Rats
Published on: June 28, 2019
Masahiro Watarai1, Masato Otsuka2, Kyoichiro Yazaki1
1Department of Cardiology, Cardiovascular Center, Ogikubo Hospital, 3-1-24, Imagawa, Suginami-ku, Tokyo, 167-0035, Japan.
Abstract:
Quantitative flow ratio (QFR) is an image-based fractional flow reserve (FFR) computed by three-dimensional quantitative coronary angiography and estimated flow velocity. Several studies have reported that QFR was rapidly computed within approximately 5 min and had a good diagnostic performance as compared with FFR. However, studies comparing QFR with instantaneous wave-free ratio (iFR) as an index with a prognostic value comparable to that of FFR are limited. Thus, we investigated the applicability of QFR with respect to iFR, both being easy-to-measure indices not requiring pharmacological hyperaemic induction. We computed QFR in prospectively enrolled 150 coronary lesions (including 50 lesions for onsite QFR analysis) in consecutive patients with intermediate stenosis evaluated by iFR. The correlation and diagnostic performance of QFR were compared using iFR as a reference. The mean QFR and iFR were 0.81 ± 0.12 and 0.89 ± 0.11, respectively. QFR and iFR exhibited a good correlation in all subjects (R = 0.70, p < 0.0001) and the onsite-analysed vessels (R = 0.74, p < 0.0001). In the receiver-operating characteristics analysis, the area under the curve of QFR predicting iFR ≤ 0.89 was 0.91. Applying the cut-off value of QFR ≤ 0.80 and iFR ≤ 0.89, the sensitivity, specificity, positive and negative predictive values were 85%, 83%, 72%, and 91%, respectively, in all subjects, and 82%, 82%, 78%, and 85%, respectively, in the onsite-analysed vessels. QFR including onsite analysis demonstrated a good correlation with iFR and a diagnostic performance comparable to that of iFR in consecutive patients with intermediate coronary stenosis, suggesting its potential as a rapidly derived index for evaluating myocardial ischaemia in clinical settings.
More Related Videos
06:39Ultrasound Based Assessment of Coronary Artery Flow and Coronary Flow Reserve Using the Pressure Overload Model in Mice
Published on: April 13, 2015
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Related Concept Videos
Odds Ratio
Poisson's Ratio
Hazard Ratio
For example, in a clinical trial...
The Ratio of X Chromosome to Autosomes
Normal male Drosophila has a ratio of one X chromosome to two sets of autosomes. In contrast, normal female...
Transformers with Off-Nominal Turns Ratios
Water Cement Ratio