Multiple time-frequency curve extraction Matlab code and its application to automatic bearing fault diagnosis under
Huan Huang1, Natalie Baddour1, Ming Liang1
1Department of Mechanical Engineering, University of Ottawa, Ottawa, Ontario, Canada.
Abstract:
Vibration signal analysis is an important technique for bearing fault diagnosis. For bearings operating under constant rotational speed, faults can be diagnosed in the frequency domain since each type of fault has a specific Fault Characteristic Frequency (FCF), which is proportional to the shaft rotational speed. However, bearings often operate under time-varying speed conditions. Additionally, the measurement of the time-varying rotational speed requires instruments, such as tachometers, which leads to extra cost and installation. With the development of time-frequency analysis, the time-varying FCFs manifest as curves in the Time-Frequency Representation (TFR). It has been shown that extracting multiple time-frequency curves from the TFR and then identifying the Instantaneous Fault Characteristic Frequency (IFCF) and Instantaneous Shaft Rotational Frequency (ISRF), bearing faults can be automatically diagnosed under time-varying speed conditions without using tachometers. However, the existing method used to identify the IFCF and the ISRF may lead to inaccurate results. In this study, the complete MATLAB© codes and a more reliable approach to use Multiple Time-Frequency Curve Extraction (MTFCE) for automatic bearing fault diagnosis under time-varying speed conditions are presented. •A Multiple time-frequency curve extraction (MTFCE) Matlab code is presented to extract multiple curves from the TFR.•Custom Matlab code for automatic bearing fault diagnosis under time-varying speed conditions without using tachometer data via the MTFCE is given and explained.•A new parameter, the allowable variance of the curve-to-curve ratio, is proposed to identify the IFCF and ISRF more reliably.
More Related Videos
Related Concept Videos
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Fault Types
For line-to-line faults occurring between phases B and C, the...
Generation Time
Mixing Time