Related Experiment Video
Updated: Jan 22, 2026

Performing Custom MicroRNA Microarray Experiments
Published on: October 28, 2011
Clinical experience of full custom-made artificial bones for the maxillofacial region
Hideto Saijo1, Yuko Fujihara1, Yuki Kanno1
1Department of Oral and Maxillofacial Surgery, Faculty of Medicine, The University of Tokyo, Hongo 7-3-1, Bunkyoku, Tokyo 113-0033, Japan.
Introduction:
Autologous, allogeneic, and artificial bones are clinically applied as graft materials for bone reconstruction, with each having their own advantages and disadvantages. Although artificial bones with various shapes are currently available, a product with a morphology that may be freely modified by operators has not yet been developed. In the present study, we developed a full custom-made artificial bone, and applied it to form the maxillofacial region. We herein report treatment outcomes.
Methods:
An artificial bone was prepared on a 3-dimensional solid model, and data of its shape was collected on CT. A full custom-made artificial bone was prepared by laminating α-tricalcium phosphate powder using an aqueous polysaccharide curing solution and the ink-jet powder-laminating device, Z406 3D Printer (DICO, USA). Subjects comprised patients who underwent maxillofacial plasty using this artificial bone between March 2006 and September 2009.
Results:
Maxillofacial plasty using the full custom-made artificial bone was applied to 23 regions in 20 patients (14 females and 6 males). The recipient region was the maxilla in 3, mandibular ramus in 13, mental region in 7, and frontal bone in 1. Postoperative courses were favorable in 18 out of the 23 regions; however, the fit was insufficient in 2 regions and the recipient regions were exposed within 1 year after surgery. Three regions were exposed 1 year or more after surgery.
Conclusion:
We developed a novel reconstruction method using a full custom-made artificial bone. Its fit with the recipient bone was considered to be important, since an ill fit between the recipient and artificial bones potentially resulting in the artificial bone being detached. Therefore, fixation is important in order to prevent the detachment, and careful course observations are required when an ill fit is concerned during the follow-up period.
Related Concept Videos
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...
IR Frequency Region: Fingerprint Region
The Eukaryotic Promoter Region
What is an Experiment?
Region of Convergence
Regional Terms
Primarily, the human body has two major regions, the axial and appendicular regions. The axial region comprises regions from the head to the abdomen and makes up the central body axis. In contrast,...