Related Experiment Video
Updated: Jan 22, 2026

Performing Vaginal Lavage, Crystal Violet Staining, and Vaginal Cytological Evaluation for Mouse Estrous Cycle Staging Identification
Published on: September 15, 2012
Post-use ring weight and residual drug content as potential objective measures of user adherence to a contraceptive
Diarmaid J Murphy1, Clare F McCoy1, Marlena Plagianos2
1School of Pharmacy, Queen's University Belfast, Belfast BT9 7BL, UK.
Objectives:
The primary aim was to investigate post-use ring weight as a potential measure of cumulative adherence to a progesterone-releasing vaginal ring.
Study Design:
We weighed and quantified residual progesterone in 115 vaginal rings following 90-day use by participants in an acceptability trial conducted in Nigeria, Senegal and Kenya. The primary objective was to correlate residual progesterone content with post-use ring weight. Secondary objectives included correlating ring weight with putative duration of ring use, and, where participants used two rings consecutively in the study, correlating residual content between these paired rings.
Results:
Mean ring weight and progesterone content of used rings was 8.62±0.24 g and 1245±245 mg respectively, versus 9.37±0.02 and 2058±21 mg for control rings. Most used rings (90.4%) had residual progesterone levels less than 85% of the nominal loading. Linear regression showed a strong positive linear trend between residual progesterone content and post-use ring weight for all rings (r2=0.82). Duration of ring use was inversely associated (p=.00020) with ring weight.
Conclusions:
Post-use ring weight is highly correlated with residual progesterone content, a benchmark objective cumulative measure of adherence, and thus potentially useful as a surrogate objective measure of cumulative adherence to a progesterone-releasing vaginal ring.
Implication Statement:
For vaginal rings containing a high initial drug loading and releasing a relatively large fraction of the initial loading during clinical use, post-use ring weight may offer a simple and inexpensive alternative to residual content testing for accurate monitoring of user adherence.
More Related Videos
12:06Collection of Post-mating Semen from the Female Reproductive Tract and Measurement of Semen Liquefaction in Mice
Published on: November 18, 2017
07:57Protocols for Vaginal Inoculation and Sample Collection in the Experimental Mouse Model of Candida vaginitis
Published on: December 8, 2011
Related Concept Videos
Potential Due to a Polarized Object
Potential Due to a Magnetized Object
The vector...
Gravitational Potential Energy for Extended Objects
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Measurement of Air Content in Concrete
The pressure method,...
Residual Stresses