Related Experiment Video
Updated: Jan 22, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Femoral Fixation Methods in Hip Resurfacing Arthroplasty: An 11-Year Retrospective Comparison of 4013 Cases
Dani M Gaillard-Campbell1, Thomas P Gross1
1Research Department, Midlands Orthopaedics & Neurosurgery, Columbia, SC.
Background:
The optimal femoral fixation method remains unclear. To evaluate the role of femoral fixation techniques in hip resurfacing, we present a comparison of 2 consecutive groups: group 1 (739 hips) with cemented femoral components; group 2 (3274 hips) with uncemented femoral components.
Methods:
We retrospectively analyzed our clinical database to compare failures, reoperations, complications, clinical results, and radiographic measurements. Groups were consecutive, so cemented cases had longer follow-up. However, all patients from both groups were at least 2 years out from surgery. Two-year clinical and radiographic data were compared. Longer-term comparison data as well as Kaplan-Meier implant survivorship curves specifically focusing on femoral failure modes were analyzed.
Results:
Kaplan-Meier 10-year implant survivorship using nontraumatic femoral failure as an end point was 98.9% for the cemented and 100% for the uncemented femoral component. The uncemented, group 2 cases showed a significantly lower raw failure rate (1.1% vs 4.6%), 2-year failure rate (0.8% vs 2.8%), 2-year femoral failure rate (0.4% vs 0.9%), and a lower combined rate of femoral complications and failures (0.6% vs 1.8%). In cases that did not fail, patient mean clinical scores, pain scores, and combined range of motion were all significantly better for group 2.
Conclusion:
We have demonstrated that in the fully porous-coated ReCap device, uncemented femoral fixation is superior to cemented fixation at 11 years follow-up (0.0% vs 1.1% late femoral loosening) in this single-surgeon cohort. Early femoral fractures also reduced from 0.8% to 0.3%, but this may be partially or completely due to a new bone density management program. This study demonstrates better femoral implant survivorship for the uncemented device compared to the cemented femoral resurfacing component for this implant design.
Related Concept Videos
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Carbon-dioxide Fixation
Evolutionary Relationships through Genome Comparisons

