Related Experiment Video
Updated: Jan 22, 2026

Focal Laser Ablation of Prostate Cancer: An Office Procedure
Published on: March 30, 2021
A surrogate urethra for real-time planning of high-dose-rate prostate brachytherapy
Heather Halperin1, Michelle Hilts2, Juanita Crook1
1BC Cancer - Kelowna, Kelowna, BC.
Purpose:
This study characterizes prostatic urethra cross-section to develop a surrogate urethra for accurate prediction of urethral dose during real-time high-dose-rate prostate brachytherapy.
Materials And Methods:
Archived preoperative transrectal ultrasound images from 100 patients receiving low-dose-rate prostate brachytherapy were used to characterize the prostatic urethra, contoured on ultrasound using aerated gel. Consensus contours, defined using majority vote, described commonalities in cross-sectional shape across patients. Potential simplified surrogates were defined and evaluated against the true urethra. The best performing surrogate, a circle of varying size (CS) was retrospectively contoured on 85 high-dose-rate prostate brachytherapy treatment plans. Dose to this recommended surrogate was compared with urethral doses estimated by the standard 6 mm circle surrogate.
Results:
Clear variation in urethral cross-sectional shape was observed along its length and between patients. The standard circle surrogate had low predictive sensitivity (61.1%) compared with true urethra because of underrepresentation of the verumontanum midgland. The CS best represented the true urethra across all validation metrics (dice: 0.73, precision: 67.0%, sensitivity: 83.2%, conformity: 0.78). Retrospective evaluation of planned doses using the CS surrogate resulted in significant differences in all reported urethral dose parameters compared with the standard circle, with the exception of D100%. The urethral dose limit (115%) was exceeded in 40% of patients for the CS surrogate.
Conclusions:
The proposed CS surrogate, consisting of circles of varying diameter, is simple yet better represents the true urethra compared with the standard 6 mm circle. Higher urethral doses were predicted using CS, and the improved accuracy of CS may offer increased predictive power for urethral toxicity, a subject of future work.
Related Concept Videos
Urethra
The anatomy of the urethra differs between males and females. In females, the urethra is short, measuring about 3–4 cm in length, and opens anterior to the vaginal opening. In males, the urethra is longer and passes through the penis, serving dual purposes: expelling urine and ejaculating semen. The male...
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
The Integrated Rate Law: The Dependence of Concentration on Time
Real Time RT-PCR
The real-time quantification of the number of amplified products is...
Anatomy of the Genitourinary System II: Bladder and Urethra
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...

