Related Experiment Video
Updated: Jan 22, 2026

Remote Limb Ischemic Preconditioning: A Neuroprotective Technique in Rodents
Published on: June 2, 2015
Does 24-h ambulatory blood pressure monitoring act as ischemic preconditioning and influence endothelial function?
Brandon G Fico1, Weili Zhu1, Hirofumi Tanaka2
1Cardiovascular Aging Research Laboratory, Department of Kinesiology and Health Education, The University of Texas at Austin, Austin, TX, 78712, USA.
Abstract:
Ischemic preconditioning can exert a powerful protection against a subsequent period of ischemia, via repeated inflation and deflation of a blood pressure cuff. Most often, damages of ischemia-reperfusion injury and benefits of preconditioning are evaluated via endothelial function. The ambulatory blood pressure monitoring constitutes repeated bouts of ischemia for 24 h. We examined whether repeated bouts of ischemia accumulated over 24 h influenced endothelial function. Twenty-two apparently healthy non-medicated middle-aged subjects 41 (8) years participated in the study. This study was registered with ClinicalTrials.gov (NCT03303404). Flow-mediated dilation (FMD) was measured as an index of endothelium-dependent vasodilation. The ambulatory blood pressure monitoring device went through an average of 110 (13) inflation/deflation cycles, which resulted in 46 (6) min of cumulative ischemic stimuli. Following 24-h of ambulatory blood pressure monitoring, FMD did not change significantly 6.6 (2.0) vs. 6.8 (2.7)%. Similarly, shear rate and reactive hyperemia were unchanged. We concluded that ambulatory blood pressure monitoring did not influence endothelium-dependent vasodilation acting via ischemic preconditioning.
More Related Videos
09:00Real-Time Monitoring and Modulation of Blood Pressure in a Rabbit Model of Ischemic Stroke
Published on: February 10, 2023
06:34Using the Electroretinogram to Assess Function in the Rodent Retina and the Protective Effects of Remote Limb Ischemic Preconditioning
Published on: June 9, 2015
Related Concept Videos
Holter Monitor: 24-Hour Monitoring
Errors occurring during blood pressure monitoring
Several factors...
Blood Pressure
Blood Pressure
The average BP in an adult is typically around 120/80 mmHg (millimeters of mercury). In this measurement, the numerator (120) indicates the systolic pressure, which is the pressure in the arteries during the contraction of the heart's ventricles as blood is expelled. The denominator (80) represents the...
Measurement of Blood Pressure
Factors affecting Blood pressure
Physiological Factors: