Related Experiment Video
Updated: Jan 22, 2026

Measuring Active and Passive Tameness Separately in Mice
Published on: August 10, 2018
Comparison of results from indoor radon measurements using active and passive methods with those from mathematical
A K Visnuprasad1, K E Reby Roy2, P J Jojo3,4
1Center for Advanced Research in Physical Sciences (CARPS), Fatima Mata National College (Autonomous), Kerala, 691001, India.
Abstract:
Computational fluid dynamics (CFD) has been used to simulate the distribution of indoor radon concentration in a naturally ventilated room. Finite volume method was employed in CFD code for the simulation of indoor radon. The simulation results were validated at 34 points in a matrix of two horizontal planes (y = 1.3 m and y = 2.1 m) using passive pinhole dosimeters and at six points using an active scintillation radon monitor. The CFD results were found to exhibit an excellent correlation with the measured values. It is concluded that CFD analysis is a powerful tool to visualize indoor radon distribution.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
20:36Predicting the Effectiveness of Population Replacement Strategy Using Mathematical Modeling
Published on: July 4, 2007
Related Concept Videos
Active versus Passive Immunity
Active Immunity
Active immunity refers to the resistance one develops...
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Fundamental Mathematical Principles in Pharmacokinetics: Mathematical Expressions and Units
One significant application of mathematics in pharmacokinetics is the characterization of drug distribution through the volume of distribution...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...