Related Experiment Video
Updated: Jan 22, 2026

Clean Sampling and Analysis of River and Estuarine Waters for Trace Metal Studies
Published on: July 1, 2016
Calibration of mathematical water quality modeling in a river basin under critical conditions
Carolina Harue Nakamura1, Marcio Ricardo Salla2, José Antônio Oliveira de Jesus3
1Department of Civil and Environmental Engineering, Bauru School of Engineering, São Paulo State University (UNESP), Bauru, SP, Brazil.
Abstract:
In order to assist with the management of water resources, this study aimed to calibrate the water quality model "Ottocoded Critical Basins Analysis" (ABaCO) in a section of the Lambari River, located in the city of Poços de Caldas, Minas Gerais, Brazil, and it is considered qualitatively critical by the "National Water Agency" (ANA). The calibration results, obtained automatically by the Microsoft Excel® tool Solver, showed good adjustments between the simulated and observed concentrations for the following parameters: total nitrogen, organic phosphorus, inorganic phosphorus, and total phosphorus, considering a visual interpretation of the graphics. The other calibrated parameters (BOD, DO, organic nitrogen, ammoniacal nitrogen, and nitrate) obtained satisfactory adjustments. When evaluating the results by coefficient of determination, it was observed that all parameters showed negative values to one or more field campaigns. However, the calibrated values of the parameters can be incorporated into the model to obtain a first view of the river's qualitative situation, aiming to plan, control, and protect water resources to assist in decision-making and to favor performance of intervention analyses of environmental control measures. PRACTITIONER POINTS: Calibration of water quality model in a section of a river located in Brazil considered qualitatively critical; The calibration occurred automatically and manually, when it was necessary, in an Excel® spreadsheet, generated from the water quality model; The automation process was performed by the Excel® Solver tool through the objective function; Through visual interpretation, it was noticed that the calibrated parameters were well adjusted to the data observed in the field; Sensitivity analysis showed that the studied parameters did not show significant differences in relation to the values calibrated for parameters.
Related Concept Videos
Quality of Water
Testing Water Quality
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Fundamental Mathematical Principles in Pharmacokinetics: Mathematical Expressions and Units
One significant application of mathematics in pharmacokinetics is the characterization of drug distribution through the volume of distribution...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Critical Region, Critical Values and Significance Level
In hypothesis testing, a sample statistic is converted to a test statistic using z, t, or chi-square distribution. A critical region is an area under the curve in probability distributions demarcated by the critical value. When the test statistic falls in this region, it suggests that the null hypothesis must be rejected. As this region contains all those values of the...

