Related Experiment Video
Updated: Jan 22, 2026

Fused Filament Fabrication FFF of Metal-Ceramic Components
Published on: January 11, 2019
Desktop Fabrication of Strong Poly (Lactic Acid) Parts: FFF Process Parameters Tuning
Vladimir E Kuznetsov1, Azamat G Tavitov2, Oleg D Urzhumtsev2
1Department of Physical Metallurgy of Non-Ferrous Metals, National University of Science and Technology "MISIS", Leninskiy Prospekt 4, NUST MISIS, 119049 Moscow, Russia. kuznetsovve@misis.ru.
Abstract:
The current study aims to evaluate the possibilities to increase part strength by optimizing the Fused Filament Fabrication (FFF) process parameters. Five different CAD models of parts with the same coupling dimensions but of different shape inherited from a recent study were converted into test samples with Ultimaker 2 3D printer. The main measure of success was the sample strength, defined as the load at which the first crack in the stressed area of the part appeared. Three different modifications to the FFF process with verified positive effect on interlayer bonding were applied. The first modification included raising the extrusion temperature and disabling printed part cooling. The second modification consisted of reduction in the layer thickness. The third modification combined the effects of the first and the second ones. For four out of five shapes tested the applied process modifications resulted in significant strengthening of the part. The shape that exhibited the best results was subject to further research by creating special printing mode. The mode included fine-tuning of three technological parameters on different stages of the part fabrication. As a result it was possible to increase the part strength by 108% only by tuning printing parameters of the best shape designed with increasing its weight by 8%.
More Related Videos
13:46A Facile and Eco-friendly Route to Fabricate PolyLactic Acid Scaffolds with Graded Pore Size
Published on: October 17, 2016
07:06Wicking Tests for Unidirectional Fabrics: Measurements of Capillary Parameters to Evaluate Capillary Pressure in Liquid Composite Molding Processes
Published on: January 27, 2017
Related Concept Videos
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Strong Acid and Base Solutions
Titration of a Strong Acid with a Strong Base
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration of a Weak Acid with a Strong Base
Titration of Polyprotic Acids with a Strong Base