Related Experiment Video
Updated: Jan 22, 2026

10:28
Compact Lens-less Digital Holographic Microscope for MEMS Inspection and Characterization
Published on: July 5, 2016
10.7K
Holographic display system with adjustable viewing angle based on multi-focus optofluidic lens
Optics Express
|June 30, 2019
Summary
A novel holographic display system uses a multi-focus optofluidic (MFO) lens to adjust the viewing angle without mechanical parts. This innovation simplifies setup and enhances holographic display capabilities.
Area of Science:
- Optics and Photonics
- Display Technology
- Fluidics
Background:
- Traditional holographic displays often require complex mechanical adjustments to alter viewing angles.
- Existing systems may lack flexibility and ease of integration.
Purpose of the Study:
- To propose and demonstrate a holographic display system with an adjustable viewing angle.
- To introduce a novel multi-focus optofluidic (MFO) lens for dynamic control of display parameters.
Main Methods:
- Development of a multi-focus optofluidic (MFO) lens using substrates and controllable liquid interfaces.
- Integration of the MFO lens with a spatial light modulator (SLM) and other optical components.
- Theoretical analysis of the MFO lens parameters and their effect on holographic viewing angles.
Main Results:
- The MFO lens focal power is tunable from -20 D (m⁻¹) to 4 D (m⁻¹).
- The viewing angle of the holographic display is adjusted dynamically by altering the MFO lens curvature.
- The system achieves adjustable viewing angles without mechanical reconfiguration, simplifying the overall setup.
Conclusions:
- The proposed MFO lens offers a viable solution for achieving adjustable viewing angles in holographic displays.
- The system's simplified design and dynamic control capabilities present new possibilities for large viewing angle holographic applications.
More Related Videos
Related Concept Videos
Adjusting a Traverse
374
In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...
374
The Anchoring-and-Adjustment Heuristic
7.7K
In order to make good decisions, we use our knowledge and our reasoning. Often, this knowledge and reasoning is sound and solid. However, sometimes, we are swayed by biases or by others manipulating a situation. For example, let’s say you and three friends wanted to rent a house and had a combined target budget of $1,600. The realtor shows you only very run-down houses for $1,600 and then shows you a very nice house for $2,000. Might you ask each person to pay more in rent to get the...
7.7K
Contact Angle
18.3K
When a solid is dipped inside a liquid, the liquid surface becomes curved near the contact. For some solid–liquid interfaces, the liquid is pulled up along the solid, while for others, the liquid surface is convex or depressed near the solid surface. This phenomenon can be explained using the concept of cohesive and adhesive forces.
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
18.3K
Econometric Views (EViews)
566
Econometric Views, often stylized as EViews, is a package that merges statistical analysis with econometric studies. It is designed to provide tools for time series analysis, forecasting, and econometric model simulation. The software originated from MicroTSP software and has evolved significantly since its inception in 1981. The history of EViews is marked by a continuous effort to enhance its computational speed and user interface. It was initially developed for large computing systems but...
566
Cranial Bones: Lateral View
4.4K
The lateral view of the cranium is dominated by temporal, sphenoid, and ethmoid bones.
The temporal bone forms the lower lateral side of the skull. The temporal bone is subdivided into several regions. The flattened upper portion is the squamous portion of the temporal bone. Below this area and projecting anteriorly is the zygomatic process of the temporal bone, which forms the posterior portion of the zygomatic arch. Posteriorly is the mastoid portion of the temporal bone. Projecting...
The temporal bone forms the lower lateral side of the skull. The temporal bone is subdivided into several regions. The flattened upper portion is the squamous portion of the temporal bone. Below this area and projecting anteriorly is the zygomatic process of the temporal bone, which forms the posterior portion of the zygomatic arch. Posteriorly is the mastoid portion of the temporal bone. Projecting...
4.4K
Renal Failure: Dose Adjustments
443
In patients with renal impairment, drugs undergo significant changes in their pharmacokinetics, which require dosage adjustments to ensure safe and effective therapy.
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
443

