Related Experiment Video
Updated: Jan 22, 2026

Determining 3D Flow Fields via Multi-camera Light Field Imaging
Published on: March 6, 2013
Extrinsic parameters calibration of multi-camera with non-overlapping fields of view using laser scanning
Abstract:
An extrinsic parameters calibration method of multi-cameras with non-overlapping fields of view (FOV) using laser scanning is presented. Firstly, two lasers are mounted on a multi-degree-of-freedom manipulator and can scan objects freely by the projected line-structured light. Then, controlling the movement of the manipulator, the line-structured light is projected into the field of view of one of the multi-cameras, and the light plane equation in the camera coordinate frame is calibrated by the target. The manipulator is moved several times in small amplitude to change the position of structured light in the field of vision of the camera and to continue to calibrate the light plane. The light plane equation of line-structured light in the manipulator coordinate frame are solved by the hand-eye calibration method. Secondly, with the help of the light planes, projected into the field of vision of other cameras to be calibrated, the light plane equation in the camera coordinate frame is calibrated, and the external parameters between the camera coordinate frame and the manipulator coordinate frame are calculated, so that the calibration of the external parameters of multiple cameras can be realized. The proposed method connects the non-overlapping multi-cameras by the laser scanning. It can effectively solve the problem of multi-camera extrinsic parameter calibration under the conditions of long working distance and complex environment light.
Related Concept Videos
The Extrinsic Apoptotic Pathway
Extrinsic and Intrinsic Pathways of Hemostasis
The Extrinsic Pathway
The extrinsic pathway of coagulation is typically initiated by tissue damage that exposes blood to tissue factor (TF), a protein released by the damaged tissue cells outside the blood vessels—this interaction with TF triggers biochemical reactions involving specific clotting factors. The key player here is Factor VII, which...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Econometric Views (EViews)

