Global coagulation function assessed by rotational thromboelastometry predicts coagulation-steady state in individual

Koji Yada1, Keiji Nogami2, Kenichi Ogiwara1

  • 1Department of Pediatrics, Nara Medical University, 840 Shijo-cho, Kashihara, Nara, 634-8522, Japan.

Emicizumab is a bispecific antibody to factor (F) IX/IXa and FX/FXa, which mimics FVIIIa cofactor function. Emicizumab prophylaxis significantly decreases bleeding events for patients with hemophilia A (PwHA). However, global hemostatic monitoring in emicizumab-treated PwHA remains poorly investigated. Using rotational thromboelastometry (ROTEM), we evaluated coagulation potentials of whole blood samples from seven emicizumab-treated PwHA who participated in ACE001JP/ACE002JP studies. Dose-dependent coagulation-enhancing effects of emicizumab to whole blood from PwHA mixed with an anti-FVIII C2 antibody in vitro were evident by non-activated ROTEM analysis (NATEM). The relationship between FVIII levels and NATEM parameters in PwHA not participating in the clinical trials demonstrated that CT + CFT inversely correlated with FVIII levels. These parameters were defined as NATEM-based grading of coagulation potential; 'T1' (FVIII < 1 IU/dL), 'T2' (1 ≤ , < 12 IU/dL) and 'T3' (12 ≤ , < 60 IU/dL). Coagulation function in emicizumab-treated PwHA was determined to be 'T2' or 'T3,' and was dependent on plasma emicizumab concentration. Improvement of NATEM-based grades corresponded with significant reduction of bleeding episodes, except for target joints, and differences were due to the time to reach the coagulation-steady state in individual patients. The NATEM analysis may be useful for intra- and inter-individual evaluation of coagulation function in emicizumab-treated PwHA.

Related Concept Videos

Coagulation01:06

Coagulation

Colloidal solids are solid particles suspended in solution. They are usually negatively charged, attracting a compact primary layer of positively charged ions, which attract more counterions to form an electrical double layer. Electrostatic repulsion between the charged double layers prevents the particles from colliding, stabilizing the colloids. These solids are often undesirable because they can contain toxins that are difficult to remove. Coagulation is a technique that helps aggregate and...
1.3K
Coagulation01:09

Coagulation

The coagulation phase is a critical part of the body's process to prevent blood loss following injury to blood vessels. It involves chemical reactions that form a clot to seal the injured area. The clotting process begins shortly after injury, within 15-20 seconds for severe damage and 1-2 minutes for minor injuries.
During the coagulation phase, clotting factors, or procoagulants, play a vital role in initiating and progressing the coagulation cascade. This cascade is a series of reactions...
9.8K
Global Climate Change01:50

Global Climate Change

Throughout its ~4.5 billion year history, the Earth has experienced periods of warming and cooling. However, the current drastic increase in global temperatures is well outside of the Earth’s cyclic norms, and evidence for human-caused global climate change is compelling. Paleoclimatology, the study of ancient climate conditions, provides ample evidence for human-caused global climate change by comparing recent conditions with those in the past.
28.8K
Steady State Concentration01:05

Steady State Concentration

A steady state refers to the level of a drug in the body once it has reached an equilibrium between administration and elimination. It represents the point at which the drug administration rate equals the drug elimination rate, resulting in a relatively constant concentration in the body over time. The dynamic equilibrium is crucial to ensure the drug's effectiveness with minimal risk of toxicity.
Most drugs are administered in repeated doses at fixed intervals or through continuous...
5.9K
Steady Flow of a Fluid Stream01:27

Steady Flow of a Fluid Stream

Consider a control volume, such as a pipe with solid boundaries, through which fluid flows and changes direction due to the impulse exerted by the resulting force from the pipe walls. In steady flow, the mass of fluid entering the control volume at a given time, t, with velocity v1, is equal to the mass leaving after infinitesimal time dt, with velocity v2.
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
685
Receiver Operating Characteristic Plot01:15

Receiver Operating Characteristic Plot

A ROC (Receiver Operating Characteristic) plot is a graphical tool used to assess the performance of a binary classification model by illustrating the trade-off between sensitivity (true positive rate) and specificity (false positive rate). By plotting sensitivity against 1 - specificity across various threshold settings, the ROC curve shows how well the model distinguishes between classes, with a curve closer to the top-left corner indicating a more accurate model. The area under the ROC curve...
479