Post-mortem computed tomography (PMCT) radiological findings and assessment in advanced decomposed bodies
Gaia Cartocci1, Alessandro Santurro1, Margherita Neri2
1Department of Anatomical, Histological, Forensic and Orthopaedic Sciences, Sapienza University of Rome, Viale Regina Elena 336, 00161, Rome, RM, Italy.
Purpose:
The aim of the study is to report radiological findings and features in advanced decomposed bodies obtained by post-mortem computed tomography (PMCT) with autopsy correlation.
Materials And Methods:
This retrospective descriptive multicentric study included 41 forensic cases examined between May 2013 and November 2016. All the bodies were PMCT-scanned prior to autopsy, and internal putrefactive state was determined using the radiological alteration index (RAI) by a radiologist with expertise in forensic radiology and a forensic pathologist trained in forensic imaging. After PMCT scans, grade of external putrefaction (GEP) was assigned during the external examination and the complete autopsy was performed by forensic pathologists.
Results:
The PMCT images evaluation revealed that the RAI index was > 61 in all bodies, corresponding to a moderate-massive presence of putrefactive gas. The gas grade was > II in correspondence of the major vessels, heart cavities, liver parenchyma, vertebra L3 and subcutaneous pectoral tissues, and varied from I to III in correspondence of the kidney. Cadaveric external examination revealed the presence of advanced transformative phenomena, with a GEP3 and GEP4 in most of the cases, with body swelling, eyes and tongue protrusion, body fluids expulsion and fat liquefaction.
Conclusion:
Radiological imaging by PMCT as an adjunct to autopsy in advanced decomposed bodies represents a useful tool in detecting post-mortem gas, even in very small amounts. A correct interpretation process of the PMCT data is essential to avoid images pitfalls, due to natural decomposition that can be mistaken for pathologic processes.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...