Decentralized Finite-time L2-L tracking control for a class of interconnected Markovian jump system with actuator

Zhaohui Chen1, Jie Tan1, Xifeng Wang2

  • 1School of Mathematics and Physics, Chongqing University of Science and Technology, Chongqing 401331, PR China.

ISA Transactions
|July 1, 2019
PubMed

Related Concept Videos

Solution Equilibrium and Saturation01:59

Solution Equilibrium and Saturation

Imagine adding a small amount of sugar to a glass of water, stirring until all the sugar has dissolved, and then adding a bit more. You can repeat this process until the sugar concentration of the solution reaches its natural limit, a limit determined primarily by the relative strengths of the solute-solute, solute-solvent, and solvent-solvent attractive forces. You can be certain that you have reached this limit because, no matter how long you stir the solution, undissolved sugar remains. The...
21.6K
Hydraulic Jump: Problem Solving01:16

Hydraulic Jump: Problem Solving

To analyze a hydraulic jump in a rectangular channel with a flow speed of 6 meters per second, follow these steps:Calculate Effective Upstream Velocity:When the downstream gate closes, a hydraulic jump forms, traveling upstream at 2 meters per second. This wave speed combines with the initial channel flow velocity, creating an effective upstream velocity.Identify Flow Velocities Before and After the Hydraulic Jump:Upstream of the hydraulic jump, the effective flow velocity includes both the...
507
Hydraulic Jump01:29

Hydraulic Jump

A hydraulic jump is a sudden rise in fluid depth in open channels, occurring when high-velocity (supercritical) flow transitions to low-velocity (subcritical) flow. This phenomenon requires an upstream Froude number greater than 1, as flows with Fr1<1 remain subcritical, making a hydraulic jump impossible due to the need for negative head loss, which violates thermodynamic principles.The characteristics of a hydraulic jump depend on the upstream Froude number and are classified as...
652
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
384
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
403
Drug Classes and Categories01:25

Drug Classes and Categories

Drugs can be classified according to their chemical composition or their intended therapeutic application. For instance, anti-infective agents that possess the ability to eliminate pathogens or suppress their growth and reproduction can be grouped based on the organisms they target or their chemical structure. Furthermore, drugs can be divided into prescription, nonprescription, or controlled substances. Prescription medications, such as antibiotics, require oversight from a licensed healthcare...
3.0K