Feasibility of closed-loop titration of norepinephrine infusion in patients undergoing moderate- and high-risk

Alexandre Joosten1, Brenton Alexander2, Jacques Duranteau3

  • 1Department of Anesthesiology and Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium; Department of Anesthesiology and Intensive Care, Hôpitaux Universitaires Paris-Sud, Université Paris-Sud, Université Paris-Saclay, Hôpital De Bicêtre, Assistance Publique Hôpitaux de Paris (AP-HP), Le Kremlin-Bicêtre, France.

Abstract

Related Concept Videos

Open and closed-loop control systems01:17

Open and closed-loop control systems

Control systems are foundational elements in automation and engineering. They are broadly categorized into open-loop and closed-loop systems. These classifications hinge on the presence or absence of feedback mechanisms, significantly influencing the system's performance, complexity, and application.
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
1.6K
Titration of a Polyprotic Acid02:08

Titration of a Polyprotic Acid

A polyprotic acid contains more than one ionizable hydrogen and undergoes a stepwise ionization process.  If the acid dissociation constants of the ionizable protons differ sufficiently from each other, then the titration curve for such polyprotic acid generates a distinct equivalence point for each of its ionizable hydrogens. Therefore, titration of a diprotic acid results in the formation of two equivalence points, whereas the titration of a triprotic acid results in the formation of three...
104.1K
Acid-Base Titration Curves02:23

Acid-Base Titration Curves

A titration curve is a plot of some solution property versus the amount of added titrant. For acid-base titrations, solution pH is a useful property to monitor because it varies predictably with the solution composition and, therefore, may be used to monitor the titration’s progress and detect its endpoint. Acid-base titration can be performed with a strong acid and a strong base, a strong acid and a weak base, or a strong base and a weak acid.
For a titration carried out for 25.00 mL of...
140.5K
Titration Calculations: Weak Acid - Strong Base03:55

Titration Calculations: Weak Acid - Strong Base

Calculating pH for Titration Solutions: Weak Acid/Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
49.1K
Titration Calculations: Strong Acid - Strong Base02:28

Titration Calculations: Strong Acid - Strong Base

Calculating pH for Titration Solutions: Strong Acid/Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
33.8K
Relative Risk01:12

Relative Risk

Relative risk (RR) is a statistical measure commonly used in epidemiology to compare the likelihood of a particular event occurring between two groups. This metric is important for evaluating the relationship between exposure to a specific risk factor and the probability of a particular outcome. It plays a crucial role in medical research, public health studies, and risk assessment. Relative risk quantifies how much more (or less) likely an event is to occur in an exposed group compared to an...
2.0K