Yasuyuki Tsushima1, Teruhiko Imamura2, Luis Landeras3
1Graduate School of Medicine, University of Tokyo, Tokyo, Japan.
Background:
The acute angle between inflow cannula and device body of HeartMate II left ventricular assist device (LVAD) (Abbott, Pleasanton, California) is associated with device thrombosis. However, most studies utilized two-dimensional (2D) angle obtained from chest roentgenogram (CXR), which is unlikely accurate. We aimed to create and validate a formula to estimate actual three-dimensional (3D) angle.
Methods:
We retrospectively reviewed the cohort undergoing HeartMate II LVAD implantation between 2008 and 2016. A formula for calculating 3D angles of the LVAD inflow cannula relative to the device body was mathematically derived, using simple 2D measurements from CXR.
Results:
The cohort included consecutive 275 patients with HeartMate II (median age: 60 [25% quartile: 51, 75% quartile: 68] years). There was no significant difference between the calculated 3D angles (from formula) and actual 3D angles (from computed tomography) from the subset group with 3D computed tomography (n = 28) (71.7° ± 13.4° vs 71.1° ± 11.5°, P = .858). Among all participants, the calculated 3D angle (from formula) was 74.4° ± 14.2°, which was significantly larger than the 2D projected angle (from CXR) (65.2° ± 11.3°, P < .001). There was no statistical difference in the calculated 3D angles (from formula) between patients with/without device thrombosis, hemorrhagic stroke, ischemic stroke, or mortality (P > .05 for all).
Conclusions:
We established a novel formula to mathematically calculate actual 3D angles between inflow cannula and device body of HeartMate II. The formula would help investigators to validate their findings of the relationship between 2D projected angle (from CXR) and device thrombosis.
More Related Videos
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
06:48Author Spotlight: Advancements in 3D Optical Imaging for Comprehensive Body Composition Assessment in Modern Research
Published on: June 7, 2024
Related Concept Videos
Chemical Formulas
Experimental Determination of Chemical Formula
Ionic Compounds: Formulas and Nomenclature
Molecular Compounds: Formulas and Nomenclature
Formula Mass and Mole Concepts of Compounds
Calculating Equilibrium Concentrations
A more...