Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in
Minki Sin1, Won-Seok Kim2, Kyujin Cho3
1Department of Medical Assistant Robot, Daegu Research Center, Korea Institute of Machinery & Materials.
Abstract:
Measuring spasticity is important in treatment planning and determining efficacy after treatment. However, the current tool used in clinical settings has been shown to be limited in inter-rater reliability. One factor in this poor inter-rater reliability is the variability of passive motion while measuring the angle of catch (AoC) measurements. Therefore, an isokinetic device has been proposed to standardize the manual joint motion; however, the benefits of isokinetic motion for AoC measurements has not been tested in a standardized manner. This protocol investigates whether isokinetic motion itself can improve inter-rater reliability for AoC measurements. For this purpose, a robotic isokinetic device was developed that is combined with surface electromyography (EMG). Two conditions, manual and isokinetic motions, are compared with the standardized method to measure the angle and subjective feeling of catch. It is shown that in 17 stroke patients with mild elbow flexor spasticity, isokinetic motion improved the intraclass correlation coefficient (ICC) for inter-rater reliability of AoC measurements to 0.890 [95% confidence interval (CI): 0.685-0.961] by the EMG criteria, and 0.931 (95% CI: 0.791-0.978) by the torque criteria, from 0.788 (95% CI: 0.493-0.920) by manual motion. In conclusion, isokinetic motion itself can improve inter-rater reliability of AoC measurements in stroke patients with mild spasticity. Given that this system may provide greater standardized angle measurements and catch of feeling, it may be a good option for the evaluation of spasticity in a clinical setting.
More Related Videos
Related Concept Videos
Reliability and Validity
The Micturition Reflex
The process begins with bladder filling, where the bladder wall stretches as urine accumulates. This stretching activates the urine storage reflex, mediated by the sacral spinal segments and the pontine storage center. Efferent sympathetic impulses stimulate the detrusor muscle to relax and the internal urethral sphincter to contract, facilitating...
Reflex Activity
A reflex exam is a diagnostic procedure performed by a healthcare professional to evaluate the functionality of a patient's...
Somatic Spinal Reflexes
One of the most well-known somatic spinal reflexes is the stretch reflex, which is activated by the sudden stretching of a muscle. This reflex involves the activation of specialized sensory receptors called muscle spindles, which are located in the muscle tissue and detect changes in the length and speed of muscle contractions. When a muscle is suddenly...
IR Frequency Region: X–H Stretching
IR Frequency Region: Alkyne and Nitrile Stretching
Comparing the stretching vibrational frequency of C≡C triple bonds with that of double and single bonds, it is evident that C≡C triple bonds exhibit a higher stretching frequency than C=C double and C–C single bonds. Similarly, the C≡N triple bond...