Background:
Personnel assigned to aircraft carriers work and live in environments where hazardous noise areas and hearing recovery spaces such as sleeping areas are in close proximity to one another. Hazardous noise exposure occurring during on-duty time periods and elevated noise levels during off-duty periods in sleeping areas may be prohibiting adequate hearing recovery, thus potentially leading to hearing loss and may lead to adverse effects on sleep, leading to crew-member fatigue. This investigation characterizes Equivalent sound level (Leq) and standardized octave band center frequency noise levels according to berthing (sleeping) area location during flight operation and nonflight operation time periods on a US Navy aircraft carrier. In addition, the investigation compares noise measurements in sleeping areas to noise levels associated with auditory rest and poor sleep quality and quantity.
Methods:
Noise levels were measured in berthing areas aboard a US Navy Nimitz-class aircraft carrier during a routine at-sea period. Sixty noise measurements were taken in eight sleeping locations. Leq in decibels 'A' weighted (dBA) and noise levels from 16 to 16 000 Hz in (dB) were measured during flight operations [Leq (flt ops)] and nonflight operations [Leq (nonflt ops)]. Leq was also measured according to sleep area shipboard locations of forward (FWD) Leq (FWD), middle (MID) Leq (MID), and rear (AFT) Leq (AFT). These data were compared to the 70 dBA American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) for effective quiet areas. In addition, these data were compared to noise levels associated with hearing loss and sleep parameters. Statistical analysis was conducted with R version 3.5.2 using an alpha level of 0.05.
Results:
Leq (flt ops) in sleeping areas was a statistically significant (P < 0.05) 6.4 dBA higher than the Leq (nonflt ops). Leq (FWD) and Leq (MID) in sleeping areas was a statistically significant (P < 0.05) 15.2 and 15.0 dBA higher, respectively, than the Leq (AFT) noise levels. Mean noise levels at standardized center (1/1) octave bands were highest between 500 and 4000 Hz, ranging from 65.2 to 69.8 dB. A total of 72% of all area Leq measurements exceeded the 70 dBA ACGIH TLV classified as effective quiet to allow for temporary threshold shift recovery. All noise measurements exceeded the World Health Organization's noise threshold where adverse effects on sleep begin.
Discussion/Conclusions:
Results suggest that sleeping area location in close proximity to relatively high noise sources and activities occurring on an aircraft carrier (i.e. flight operations) increase noise levels in sleeping areas. These findings raise serious concerns since high noise exposures both on duty and during off-duty/sleeping periods may inhibit auditory recovery from hazardous noise exposures. In addition, results suggest noise levels in sleeping areas are high enough to evoke negative sleep effects.
More Related Videos
09:36Continuous-Wave Propagation Channel-Sounding Measurement System - Testing, Verification, and Measurements
Published on: June 25, 2021
05:33Measuring Biophysical and Psychological Stress Levels Following Visitation to Three Locations with Differing Levels of Nature
Published on: June 19, 2019
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Electron Carriers
Over the many stages of cellular respiration, glucose breaks down into carbon dioxide and water. Electron carriers pick up electrons lost by glucose in these reactions, temporarily storing and releasing them into the electron...
Ratio Level of Measurement
A set of data measured using the ratio scale takes care of the ratio problem and provides complete information. Ratio scale data are like interval scale data, except they have a zero point and ratios can be calculated....
Ordinal Level of Measurement
Data measured using an ordinal scale are similar to nominal scale data, but there is one major difference. The ordinal scale data can be ordered. An example of ordinal scale data is a list of the top five national parks...
Interval Level of Measurement
Data measured using the interval scale are similar to ordinal level data because they have a definite arrangement. However, in the interval level of measurement, the differences between data values are meaningful even though the data does not have a starting point.
Temperature is measured using the interval scale. It is measurable data, and the difference between...
Nominal Level of Measurement
The data that cannot be measured but can be grouped into categories fall under the nominal level of measurement. Data that is measured using a nominal...