Related Experiment Video
Updated: Jan 22, 2026

Author Spotlight: Innovative Techniques for ROS Detection and Implications for Platelet Research
Published on: March 29, 2024
Photoacoustic Detection of Superoxide Using Oxoporphyrinogen and Porphyrin
Jean Michél Merkes1, Magnus Rueping1,2, Fabian Kiessling3
1Institute of Organic Chemistry , RWTH Aachen University , Landoltweg 1 , D52074 Aachen , Germany.
Abstract:
The superoxide (O2•-) ion is a highly reactive oxygen species involved in many diseases; hence, its noninvasive detection is desirable to identify the onset of pathological processes. Here, we employed photoacoustic (PA) spectroscopy, which enables imaging at ultrasound resolution with the sensitivity of optical modality, for the first time to detect O2•-, using stimuli-responsive contrast agents. meso-(3,5-Di-tert-butyl 4-hydroxyphenyl) porphyrins and oxoporphyrinogens were used as PA contrast agents, which trap the O2•- and enable its detection. The trapped O2•- increased the PA signal amplitude of chromophores up to 9.6-fold, and induced a red-shift in the PA signal maxima of up to 225 nm. Therefore, these trigger-responsive probes may be highly valuable as smart diagnostic PA probes to investigate pathological events stimulated by O2•- species.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...