Unplugging the Drain: Treatment of a Rare Late Complication of Cardiac Resynchronization Therapy
Faheemullah Beg1, Tanushree Agrawal2, Ashrith Guha3
1Cardiovascular Disease, Houston Methodist Hospital, Houston, USA.
Insights
Central vein thrombosis (CVT), a rare complication, caused chylothorax in a heart failure patient. Balloon angioplasty successfully treated the occluded vein, resolving the effusion.
Area of Science:
- Cardiology
- Vascular Medicine
- Pulmonology
Background:
- Central vein thrombosis (CVT) is an uncommon cause of chylothorax.
- Heart failure patients often have indwelling devices that can lead to venous complications.
Observation:
- A 65-year-old male with end-stage heart failure presented with shortness of breath and a large pleural effusion.
- Diagnostic workup confirmed chylothorax and revealed bilateral brachiocephalic vein occlusion despite anticoagulation.
Findings:
- The patient's chylothorax was secondary to central vein thrombosis.
- Successful treatment was achieved with balloon angioplasty of the occluded right brachiocephalic vein, leading to effusion resolution.
Implications:
- This case highlights a rare complication of cardiac devices in heart failure patients.
- Reversible central vein thrombosis causing chylothorax can be effectively treated with angioplasty.
Abstract:
Central vein thrombosis (CVT) is a rare cause of chylothorax. We report a patient with chylothorax secondary to CVT, despite being on anticoagulation, who was successfully treated with balloon angioplasty of the occluded vein. A 65-year-old male presented with shortness of breath of one-month duration. He had end-stage heart failure and was on milrinone infusion. Physical exam was consistent with elevated central venous pressure. Chest x-ray showed a large left-sided pleural effusion. Right heart catheterization (RHC) showed normal right atrial pressure and normal pulmonary capillary wedge pressure. Diagnostic thoracentesis was consistent with chylothorax. A venogram revealed bilateral brachiocephalic vein occlusion. The right brachiocephalic vein was recanalized by angioplasty, which led to resolution of pleural effusion. Our case not only highlights the identification of a rare complication of a common device (i.e., cardiac resynchronization therapy defibrillator) used in heart failure patients but also highlights the treatment for this rare but reversible complication.
More Related Videos
Related Concept Videos
Hemodialysis II: Procedure and Complications
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
Gene Therapy
Diabetes: Symptoms, Diagnosis, and Complications
Pneumonia III: Complications and Assessment
Asthma-III: Symptoms and Complications
Classification of Asthma