Initial Results From a New Model of Posterior Chamber Implantable Phakic Contact Lens: IPCL V2.0
1Clínica de Ojos Dr. Nano. Centro Panamericana, Buenos Aires, Argentina.
Abstract:
The aim of this study was to evaluate the corneal safety, intraocular pressure (IOP), vault and refractive efficiency of the new implantable phakic contact lens, IPCL V2.0 (Care Group, India). A prospective case series study was performed to evaluate 100 consecutive surgeries with IPCL V2.0 (spherical and toric models). Refractive results, corneal endothelial cell density (CD) and central corneal thickness (CCT) were measured at baseline and 6 months after surgery. Intraocular pressure was measured at baseline, 1 day and 6 months, and vault, 3 and 6 months after surgery. Surgical complications and cataract development were also evaluated. The mean corneal endothelial CD decreased by 2.9% with a statistically significance difference (p: 0.03). The mean CCT decreased by 0.87% at 6 months postoperative, without a statistical significance difference (p: 0.35). The mean ± standard deviation (SD) of IOP at baseline was 13.72 ±1.4 mm Hg, at 1 day postoperative was 13.88 ±1.2 mm Hg, and at 6 months was 13.62 ±1.3 mm Hg. These differences were not statistically significant (p: 0.37). The difference in vault between 3 and 6 months after surgery was not statistically significant (p: 0.97). The coefficient of correlation between the attempted versus achieved spherical equivalent (SE) change was R2: 0.958. Postoperative SE was between -0.50 D to +0.50 D in 52% of cases. The remaining of the eyes had SE values ranging from -1.5 D to +1.35 D. No intra or postoperative complications occurred and specifically cataract was not developed. The corneal endothelial CD, CCT, vault and IOP remained stable 6 months after surgery. Refraction was improved and the IPCL V 2.0 was implanted safely.
Related Concept Videos
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...
Initiation of Translation
Contact-dependent Signaling
Gap Junctions
In animal cells, gap junctions are formed...
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Transcription Initiation
The promoters and enhancers and their accessory proteins allow tight regulation of...
S-Cdk Initiates DNA Replication
Two states at the origin of replication
In eukaryotes, the initiation of replication occurs at many sites on the chromosomes, called the origins of...