Related Experiment Video
Updated: Jan 22, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Cross-Linked Versus Conventional Polyethylene for Long-Term Clinical Outcomes After Total Hip Arthroplasty: A
Jiangyuan Shi1, Weicong Zhu2, Shaohua Liang1
1Department of Orthopedics, Guangzhou Red Cross Hospital, Medical College, Jinan University, Guangzhou, China.
Insights
Cross-linked polyethylene (HXLPE) significantly reduces revision surgery and osteolysis in total hip arthroplasty compared to conventional polyethylene (CPE). While HXLPE improves clinical and radiographic outcomes, functional results remain similar between the two materials.
Area of Science:
- Orthopedic Surgery
- Biomaterials Science
- Medical Engineering
Background:
- Conventional polyethylene (CPE) liners in total hip arthroplasty (THA) are associated with osteolysis and revision surgery.
- Cross-linked polyethylene (HXLPE) was developed to mitigate these issues.
- Long-term efficacy of HXLPE versus CPE requires comprehensive evaluation.
Purpose of the Study:
- To systematically review and meta-analyze the long-term efficacy of HXLPE compared to CPE in preventing revision surgery and radiological osteolysis after THA.
- To assess differences in polyethylene wear between HXLPE and CPE liners.
- To evaluate functional outcomes associated with HXLPE and CPE use in THA.
Main Methods:
- A systematic search of PubMed, Embase, and Cochrane Library was performed up to September 2018.
- Included studies comprised eight randomized controlled trials (RCTs) and six observational studies.
- Data were pooled using Stata software; study quality was assessed using the Cochrane risk-of-bias tool and Newcastle-Ottawa scale.
Main Results:
- HXLPE demonstrated a significant reduction in total revisions (78%) and radiological osteolysis (80%) compared to CPE (p < 0.001).
- Subgroup analyses confirmed HXLPE's efficacy in preventing revision and osteolysis.
- HXLPE exhibited significantly lower linear wear and head penetration rates than CPE (p < 0.001), with no difference in functional outcomes.
Conclusions:
- HXLPE significantly improves clinical and radiographic outcomes in THA compared to CPE.
- HXLPE effectively reduces polyethylene wear, leading to fewer revisions and less osteolysis.
- Functional outcomes do not differ significantly between HXLPE and CPE in the long-term follow-up.
Abstract:
Background: Cross-linked polyethylene (HXLPE) liners have been used for total hip arthroplasty (THA) to address the problem of osteolysis and revision surgery associated with conventional polyethylene (CPE) liners. This systematic review and meta-analysis investigated the long-term efficacy of HXLPE in preventing revision surgery and radiological osteolysis in comparison to CPE. Materials and Methods: A comprehensive search of PubMed, Embase, and the Cochrane Library from their respective inception to September 2018 was conducted to identify potential candidate articles. Data were pooled using Stata software 14.0. The quality of randomized controlled trials (RCTs) and observational studies was assessed by two different authors using the Cochrane risk-of-bias tool and the Newcastle-Ottawa scale (NOS), respectively. Results: Eight RCTs and six observational studies were included in this review. The pooled results significantly favored HXLPE over CPE in terms of total number of revisions and radiological osteolysis, with a risk reduction of 78% (95% confidence interval [CI] 0.13-0.36; p < 0.001) and 80% (95% CI 0.13-0.29; p < 0.001), respectively. Additionally, subgroup analyses of pooled data from RCTs and observational studies both showed the efficacy of HXLPE in the prevention of revision and osteolysis. Polyethylene wear in the HXLPE group was significantly less than that in the CPE group in terms of linear wear rates and head penetration rates (both p < 0.001). No significant differences were observed with regard to functional outcomes. Conclusions: The current evidence shows that HXLPE significantly improved the clinical and radiographic outcomes, but not the functional outcomes, in comparison to CPE in long-term follow-up.
Related Concept Videos
Crossing Over
The homologous pairs of sister chromosomes—one from the maternal and one from the paternal genome—then begin to align alongside each other lengthwise, matching corresponding DNA positions in a process...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Covalently Linked Protein Regulators
These groups modify specific amino acids in a protein....
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Monohybrid Crosses