Related Experiment Video
Updated: Jan 22, 2026

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Methodological quality and redundancy of systematic reviews that compare endarterectomy versus stenting for carotid
Juan Fulgencio Welko Mendoza1, Carolina de Oliveira Cruz Latorraca1, Ricardo de Ávila Oliveira1,2
1Discipline of Evidence-Based Medicine, Universidade Federal de São Paulo (Unifesp), São Paulo, São Paulo, Brazil.
Abstract:
A review of systematic reviews (SRs) and a critical appraisal study was conducted at Escola Paulista de Medicina, Universidade Federal de São Paulo (Unifesp). The objectives of this review are (1) to identify all published SRs comparing the effectiveness and safety of carotid endarterectomy (CEA) versus carotid artery stenting (CAS) for carotid artery stenosis, (2) to assess their methodological quality and (3) to compare the primary studies contained in each SR. We included 17 SRs published between 2005 and 2017. None of the SRs fulfilled all items of AMSTAR-2. The overall confidence in the results was graded as critically low for 16 SRs (94%) and low for 1 SR (6%). Five items were judged inadequate in all SRs: reference to a published protocol, explanation to the selection of study design, comprehensive search of the literature, methods for statistical combination of findings and consideration of the risk of bias on the results of meta-analysis. In total, 15 randomised clinical trials (RCTs) were included at least in one SR. The number of included RCTs in each SR was inconsistent (4 to 15) and was not related to the year of publication of the SR. Our study found redundant and low methodological quality SR comparing CAS versus CEA for carotid stenosis.
More Related Videos
08:26Design of a Biocompatible Drug-Eluting Tracheal Stent in Mice with Laryngotracheal Stenosis
Published on: January 21, 2020
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Review and Preview
Percentiles are a type of fractile that partition data into...
Review and Preview
Random and Systematic Errors
Mitral Stenosis I: Introduction
Systematic Sampling Method
Systematic sampling is one of the simplest methods...