Noninvasive and Wearable Respiration Sensor Based on Organic Semiconductor Film with Strong Electron Affinity
Peihua Zhu1, Shanshan Li1, Xinyue Jiang1
1School of Chemistry and Chemical Engineering , University of Jinan , Jinan 250022 , People's Republic of China.
Abstract:
Interventional medical detection techniques require expensive devices and cause inconvenience and discomfort to the human body, which restricts their application to the frequency and duration of measurements. A noninvasive respiration test is urgently required for the next-generation medical technologies in early disease warning and postoperative monitoring. This article describes a noninvasive and wearable sensing device that shows high sensitivity toward acetone in respiratory gases with excellent stability, low energy consumption, and reliable flexibility. To obtain such a sensor, the organic semiconductor compound La(TBPP)(TBNc) (TBPP = tetrakis(4-tert-butylphenyl)porphyrin; TBNc = tetrakis(4-tert-butylphenyl)naphthalocyanine) was synthesized and further self-assembled into a highly ordered flexible film via a simple solution-vapor annealing method. The fabricated flexible film was deposited on an interdigitated electrode with poly(ethylene terephthalate) substrate and employed as an electrical identification component for a respiration sensor. Thanks to the attractive electron-transfer properties of highly ordered films and strong electron affinity of La(TBPP)(TBNc) molecules, the as-prepared sensor shows a low detection limit (200 ppb) and acceptable selectivity. The wrinkled/rippled structure of films endows the fabricated sensors with the ability of mechanical flexibility. More importantly, the experimental results suggest the potential application of acetone identification in real respiratory gases and provide a new concept for the development of noninvasive and wearable medical diagnostic devices.
Related Concept Videos
Electron Affinity
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Strong Acid and Base Solutions
Titration of a Strong Acid with a Strong Base
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration of a Weak Acid with a Strong Base