The impact of macroscopic on-site evaluation using filter paper in EUS-guided fine-needle biopsy
Dongwook Oh1, Dong-Wan Seo1, Seung-Mo Hong2
1Department of Gastroenterology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
Background And Objectives:
EUS-guided tissue acquisition with rapid on-site cytologic evaluation (ROSE) has been used to increase the diagnostic yield. However, ROSE is not available in many centers. To date, only a few studies have assessed the adequacy of histologic cores in macroscopic on-site evaluation (MOSE) during EUS-guided fine-needle biopsy (EUS-FNB). Blood contamination of histologic core specimens lowers the sample quality and the diagnostic yield. Therefore, we evaluated the efficacy of MOSE using filter paper to increase the adequacy of histologic core specimens while minimizing blood contamination.
Materials And Methods:
Seventy-nine consecutive patients with an intraabdominal mass underwent EUS-FNB between March 2017 and October 2018. Histologic specimens obtained using EUS-FNB were expelled onto filter paper, and the histologic procurement rate on MOSE was evaluated.
Results:
EUS-FNB using a 20-gauge Procore needle or a 22-gauge Acquire needle was successful in all patients. The mean number of needle passes was 2.8 ss0.8. Visible histologic cores were observed in 94.9% (75/79) of the patients. Blood-contaminated specimens with scanty histologic cores were obtained in 5.1% (4/79) of the patients. On microscopic examination, 92.4% (73/79) of the histologic samples were graded as optimal. The diagnostic accuracy, sensitivity, and specificity were 94.5%, 94.3%, and 100%, respectively. Mild postprocedural adverse events occurred in 2 patients (2.5%: n = 1, transient fever; n = 1, acute pancreatitis).
Conclusions:
MOSE using filter paper provided adequate histologic samples while minimizing blood contamination. MOSE can also increase the diagnostic accuracy when ROSE is not available.
Related Concept Videos
Passive Filters
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Active Filters
Fineness of Cement
Direct...
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Impact of Groups on Groups
Impact
When particles with different initial velocities collide, they induce deformation by applying equal and opposite impulses. At the point of maximum deformation, the particles move together with...