Extended field radiotherapy measurements in a single shot using a BaFBr-based OSL-film
Robin De Roover1, Charlien Berghen1, Gert De Meerleer1
1Department of Oncology, Radiation-Oncology, KU Leuven, University Hospitals Leuven, 3000 Leuven, Belgium.
Abstract:
This work evaluated the use of a class solution specific calibration for an extra-large BaFBr-based optically stimulated luminescence film (OSL; 43 × 35 cm2; Z eff = 4.55). The clinical need for such large dosimeters follows from the increased use of extended-field radiation therapy (EFRT). E.g. for prostate cancer EFRT is currently used in the first prospective trial investigating the benefit of adding elective irradiation of the para-aortic lymph nodes in pN1 prostate cancer. The full extent of these EFRT dose distributions is not covered by the well-established standard sized radiochromic film or 2D detector arrays. Here we investigate an OSL calibration methodology, that tackles BaFBr-based OSL's inherent energy dependence by a class solution specific calibration. 10 EFRT treatment plans used in the PART trial were investigated. One plan was used to build a class solution specific bilinear calibration model, that distinguishes between in-field and penumbra dose contributions. The effect of this calibration was evaluated with respect to a standard linear calibration, using standard IMRT patterns, the nine remaining patient plans, and to smaller prostate treatment plans. A single OSL-dosimeter could be reused for all measurements. The dosimeter captured the full extent of the dose distributions (maximum EFRT field size = 33.5 cm). The bilinear correction reduced the residual dose differences from above 10% to an average of 0.7% (max 3.6%) in comparison with a Monte Carlo simulation. Consequently global gamma agreement scores (3%-3 mm) of 95.5% ± 2.7% were reached. A more strict local evaluation resulted in an average gamma-agreement score of 93.3% ± 3.2%. The BaFBr-based OSL film, with reduced Z eff requires a class-solution specific correction. The current work shows that such a correction can be as simple as a bilinear residual dose correction driven by the measured signal. As far as we know this is the first 2D dosimeter combining reusability, a sub-mm resolution, and a size covering the typical EFRT treatment plans.
More Related Videos
09:57Obtaining Quality Extended Field-of-View Ultrasound Images of Skeletal Muscle to Measure Muscle Fascicle Length
Published on: December 14, 2020
08:43Effect of Bending on the Electrical Characteristics of Flexible Organic Single Crystal-based Field-effect Transistors
Published on: November 7, 2016
Related Concept Videos
Gravitational Potential Energy for Extended Objects
Electric Field
In the new picture, imagine that the first charge sets up an electric field independent of all other charges in the universe. When another charge comes in its vicinity, the second charge experiences an electric force depending on the electric field at that point. The source charge does not...
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Electromagnetic Fields
However, the observation of...
Field Effect Transistor
Crystal Field Theory - Octahedral Complexes
To explain the observed behavior of transition metal complexes (such as colors), a model involving electrostatic interactions between the electrons from the ligands and the electrons in the unhybridized d orbitals of the central metal atom has been developed. This electrostatic model is crystal field theory (CFT). It helps to understand, interpret, and predict the colors, magnetic behavior, and some structures of coordination compounds of transition metals.
CFT focuses on...