A Novel Universal Approach for Temperature Correction on Frequency Domain Spectroscopy Curve of Transformer Polymer
Jiefeng Liu1, Xianhao Fan1, Yiyi Zhang2
1College of Electrical Engineering, Guangxi University, Nanning 530004, China.
Abstract:
It is a fact that the frequency domain spectroscopy (FDS) curve at different temperatures can be corrected by the shift factor (αT) extracted from the master curve. However, the αT and master curve reported by previous works are distinctive due to the difference in the construction algorithm. Therefore, it is of great significance to report a universal approach for extracting αT. In this work, the unaged oil-immersed pressboards with different moisture content (mc%) are firstly prepared and selected as the research specimen. Then, the αT of FDS curves on the above pressboard is extracted based upon the master curve technique. The influence mechanism under the various test temperature (T) and mc% is therefore analyzed so as to establish a universal model for predicting the αT. The present findings reveal that the αT value extracted from FDS curves is both temperature-dependent and moisture-dependent. In addition, the predicted αT is not only suitable for temperature correction on FDS curve of same type pressboard with different insulation conditions (moisture contents and aging degrees), but also maintains considerable accuracy when applied to different types of pressboard. Therefore, the obtained conclusions will provide a universal method for temperature correction on FDS curve of transformer polymer insulation.
Related Concept Videos
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear....
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...