Related Experiment Video
Updated: Jan 22, 2026

Fabrication of a Functionalized Magnetic Bacterial Nanocellulose with Iron Oxide Nanoparticles
Published on: May 26, 2016
A prospective pilot study on MRI visibility of iron oxide-impregnated polyvinylidene fluoride mesh after ventral
K E Laitakari1,2, J K Mäkelä-Kaikkonen3,4, E Pääkkö5
1Division of Gastroenterology, Department of Surgery, University Hospital of Oulu, Oulu, Finland. kirsi.laitakari@fimnet.fi.
Background:
Magnetic resonance imaging (MRI) provides excellent information about pelvic anatomy after ventral rectopexy, but the position of the conventional mesh is not seen constantly. Iron oxide-impregnated polyvinylidene fluoride (PVDF) meshes are proven to have MRI visibility in hernia or vaginal reconstructive surgery. This prospective pilot study was designed to assess the visualization, position, and shape of the magnetic resonance (MR)-visible synthetic pelvic mesh used in minimally invasive ventral rectopexy.
Methods:
Eight patients with pelvic organ prolapse were recruited for laparoscopic (LVMR) or robotic-assisted ventral mesh rectopexy (RVMR) with a synthetic MR-visible PVDF mesh. A follow-up visit was scheduled at 3 months after surgery. MR imaging was performed to evaluate the position and dimensions of the mesh and anatomical result. The visibility of the mesh in each sequence was assessed subjectively.
Results:
The visibility of the mesh was best on T1-weighted flash images. The mesh was also well visualized on T2-weighted sagittal images. T2-weighted images, in general, provided best visualization of the surrounding anatomical structures and enabled assessment of the mesh fixation.
Conclusions:
T2 sagittal and T1-weighted flash images provide the best information about the position and integrity of the iron oxide-impregnated PVDF mesh after LVMR or RVMR with a short examination time.
Related Concept Videos
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Mesh Analysis
A fundamental concept in mesh analysis is the definition of meshes and mesh currents. A mesh is a closed...
Pilot and Numeric Relaying
Oxidation Numbers
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Mesh Analysis for AC Circuits
The process of harmonizing these impedances begins with a clear understanding of the input and output signals. Once these signals are known, the...

