Related Experiment Video
Updated: Jan 22, 2026

Fabrication of Three-dimensional Paper-based Microfluidic Devices for Immunoassays
Published on: March 9, 2017
High-resolution temporally resolved chemiluminescence based on double-layered 3D microfluidic paper-based device for
Fang Li1, Jiachang Liu1, Lei Guo1
1Anhui Province Key Laboratory of Advanced Catalytic Materials and Reaction Engineering, School of Chemistry and Chemical Engineering, Hefei University of Technology, Hefei, Anhui, 230009, People's Republic of China.
Abstract:
In this work, a double-layered three-dimensional (3D) microfluidic paper-based analytical device (μPAD) with high resolution temporally resolved chemiluminescence (CL) emissions were designed for multiplexed CL analysis. The temporally resolved CL emissions were obtained by virtue of the 3D branched microfluidic channel design, which create time delays for luminol transported from one detection zone to another. The peak intensity and peak shape of the temporally resolved CL emissions were quite stable and base-line separated with resolution as high as 21.2-24.4. Then, the fabricated μPAD was applied to multiplexed determination of glucose, lactate, cholesterol, and choline as model analytes. The sample was added to four detection zone modified with CL catalyst cobalt ion and different oxidase by virtue of chitosan. When luminol flowed to μPAD, four temporally resolved CL peaks were successively generated from the cobalt ion catalyzed CL reactions between luminol and generated H2O2 from the specific enzymatic reactions between the oxidase and the analytes. The generated four CL emission peaks in the CL kinetic curve increased in proportion to the concentrations of glucose, lactate, cholesterol, and choline, respectively. Finally, four linear calibration curves were obtained for the detection of glucose (0.01-1.0 mmol/L), lactate (0.02-5.0 mmol/L), cholesterol (0.01-0.4 mmol/L), and choline (0.001-1.0 mmol/L). The detection limits were as low as 8 μmol/L, 15 μmol/L, 6 μmol/L, and 0.07 μmol/L for glucose, lactate, choline, and cholesterol detection, respectively. The present work provides a new strategy for the fabrication of simple and sensitive 3D μPAD with high resolution temporally resolved CL emissions for multiplexed CL analysis, which holds great application potential for point-of-care diagnosis.
Related Concept Videos
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
DNA Base Pairing
Classification of Titrimetric Analysis Based on Reaction Types
Titrations between an acid and a base lead to neutralization reactions that form...
Base Excision Repair
The first step of...
Lewis Acids and Bases
A coordinate covalent bond (or dative bond) occurs when one of the atoms in the bond provides both bonding electrons. For example, a coordinate covalent bond occurs when a water molecule combines with a hydrogen ion to form a hydronium ion. A coordinate covalent bond also results when...