Standardization of Temporal Bone CT Planes across a Multisite Academic Institution
J P Guenette1, L Hsu2, B Czajkowski2
1From the Division of Neuroradiology, Brigham & Women's Hospital, Boston, Massachusetts. jpguenette@bwh.harvard.edu.
Background And Purpose:
Variable head positioning in the CT gantry results in variable and inconsistent temporal bone imaging planes. Our aim was to evaluate whether an automated postprocessing algorithm or an educational intervention with postprocessing by a technologist could result in consistent temporal bone image reformations into planes referenced to the lateral semicircular canal.
Materials And Methods:
Instructions to reformat small-FOV images in planes referenced to the lateral semicircular canal were posted at 12 CT scanner consoles and e-mailed to 65 CT technologists at a single multisite institution. Automated reformatted images were also produced. The angles between the technologist- and automated-reformatted axial image planes and lateral semicircular canal planes were measured. Group differences were calculated with Mann-Whitney-Wilcoxon tests. Differences in homogeneity of variances were calculated with Fligner-Killeen tests.
Results:
Two hundred ten temporal bones were imaged in 4 months following the intervention. Reformats by technologists were accurate in 87% of the axial and 81% of the coronal planes, with a trend toward improvement with time. Eighty percent of incorrectly reformatted images occurred at off-site, inpatient, and emergency department scanners. The error angle was significantly lower for technologist-reformatted images (median, 4.9°) than for acquisition plane images (median, 14.6°; P = 3 × 10-14) or automated-reformatted images (median, 13.8°; P = 9 × 10-13). The angle error variance was significantly more homogeneous for technologist-reformatted images (P = 3 × 10-8) and automated-reformatted images (P = 1 × 10-5) than for acquisition plane images.
Conclusions:
Both technologist and automated reformatting of temporal bone images resulted in significantly less imaging plane variance compared with images reformatted in the acquisition plane, but reformatting by technologists remains necessary at our institution given our preference for standardized planes referencing the lateral semicircular canals.
Related Concept Videos
Work Done Over an Inclined Plane
The work done by gravity to move a rigid body, or the work done by an opposing force to move a rigid body against gravity, can be calculated using the center-of-mass framework. It is the line integral of the force of gravity over the path, considered positive if...
Body Planes
The sagittal plane is the plane that divides the body or an organ vertically into right and left sides. If this vertical plane runs directly down the middle of the body resulting in equal division, it is called the midsagittal or median...
Transformation of Plane Stress
Plane Electromagnetic Waves I
The EM field is assumed to be a...
Plane Electromagnetic Waves II
Plane Potential Flows
Uniform...